Evidence map›Paper›PMID 35069855›Full record

ReviewExperimental and therapeutic medicine2022

Continuous glucose monitoring devices: A brief presentation (Review).

Doina Andrada Mihai, Diana Simona Stefan, Daniela Stegaru, Georgiana Elena Bernea, Ileana Adela Vacaroiu, Toma Papacocea, Mircea Ovidiu Denis Lupușoru, Adriana Elena Nica, Ovidiu Stiru, Dorin Dragos and 1 more

Open access · diamondAbstract readReview
In one paragraph

Review in Experimental and therapeutic medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 1 pooled it
4.0field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 1 synthesis or guideline pooled it, 35 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Strategies for optimization of hypoglycemia rat models.Animal models and experimental medicine · 2025
    Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Review
  10. Criteria for Personalised Choice of a Continuous Glucose Monitoring System: An Expert Opinion.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2024
    Article
  11. Article
  12. Targeting PI3K/AKT/mTOR and MAPK Signaling Pathways in Gastric Cancer.International journal of molecular sciences · 2024
    Review
  13. Article
  14. Review
  15. Article
  16. Review
  17. Review
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 2 countries.

Doina Andrada MihaiDiscipline of Diabetes, Nutrition and Metabolic Diseases, Faculty of Medicine, 'Carol Davila' University of Medicine and Pharmacy, 'N. C. Paulescu' Institute of Diabetes, Nutrition and Metabolic Diseases, 020021 Bucharest, Romania.
Diana Simona StefanDiscipline of Diabetes, Nutrition and Metabolic Diseases, Faculty of Medicine, 'Carol Davila' University of Medicine and Pharmacy, 'N. C. Paulescu' Institute of Diabetes, Nutrition and Metabolic Diseases, 020021 Bucharest, Romania.
Daniela StegaruDiscipline of Diabetes, Nutrition and Metabolic Diseases, Faculty of Medicine, 'Carol Davila' University of Medicine and Pharmacy, 'N. C. Paulescu' Institute of Diabetes, Nutrition and Metabolic Diseases, 020021 Bucharest, Romania.
Georgiana Elena Bernea'N. C. Paulescu' Institute of Diabetes, Nutrition and Metabolic Diseases, Diabetes Department II, 020474 Bucharest, Romania.
Ileana Adela VacaroiuDepartment of Nephrology, Faculty of Medicine, 'Carol Davila' University of Medicine and Pharmacy, 020021 Bucharest, Romania.
Toma PapacoceaDepartment of Neurosurgery, Faculty of Medicine, 'Carol Davila' University of Medicine and Pharmacy, 020021 Bucharest, Romania.
Mircea Ovidiu Denis LupușoruDiscipline of Physiology, Faculty of Medicine, 'Carol Davila' University of Medicine and Pharmacy, 020021 Bucharest, Romania.
Adriana Elena NicaDepartment of Orthopedics, Anesthesia Intensive Care Unit, Faculty of Medicine, 'Carol Davila' University of Medicine and Pharmacy, 020021 Bucharest, Romania.
Ovidiu StiruDepartment of Cardiovascular Surgery, Faculty of Medicine, 'Carol Davila' University of Medicine and Pharmacy, 020021 Bucharest, Romania.
Dorin DragosDepartment of Medical Semiology, Discipline of Internal Medicine I and Nephrology, Faculty of Medicine, 'Carol Davila' University of Medicine and Pharmacy, 020021 Bucharest, Romania.
Octavian Gabriel OlaruDepartment of Obstetrics and Gynecology, Faculty of Medicine, 'Carol Davila' University of Medicine and Pharmacy, 020021 Bucharest, Romania.
Carol Davila University of Medicine and Pharmacy · RODeutsches Diabetes-Zentrum e.V. · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As diabetes prevalence is continuously increasing, better management is needed to achieve blood glucose control, in order to prevent complications and lessen the burden of this disease. Since the first measurement of glycosuria at the beginning of the 1900s', huge advances were made in monitoring glycemia. Continuous glucose monitoring systems revolutionized diabetes management, especially for patients with type 1 diabetes. Avoiding glycemic variability and maintaining optimal glycemic control is crucial for the evolution of patients with type 1 diabetes. The usefulness of glycemic monitoring devices can be extended to patients with type 2 diabetes. It is also important to note that in those patients at risk of developing high glycemic variability (e.g. patients with advanced chronic kidney disease), continuous glycemic monitoring may improve their prognosis. These monitoring systems can be classified according to the analytical method, the degree of invasiveness, the data availability and the mode of usage. The technology is constantly improving in bioanalytical performance, biocompatibility, length of wearing time, safety and clinical features. The aim of this review was to briefly present the main characteristics of glucose biosensors, glucose monitoring systems and their clinically utility.

Indexed as

biosensorscontinuous glucose monitoring systemsdiabetesglucose detection technologiespolymers

Identifiers

PMID35069855
PMCPMC8764584
OpenAlexW4205742618

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked