ArticleOral radiology2022
Effect of enveloping and disinfection methods on artefact formation on enveloped PSP plate images.
Article in Oral radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Analysis of image defects in digital intraoral radiography based on photostimulable phosphor plates.Oral radiology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo investigate the artefacts caused by different disinfection and protection methods that can be used for infection control of photostimulable phosphor (PSP) plates.
methodsThe plates that were enveloped with single or double envelopes were sprayed with an alcohol-containing solution or wiped with an alcohol-containing tissue. Four PSP groups with two plates in each group were formed (A = wiping single envelope, B = wiping double envelopes, C = spraying onto single envelope, and D = spraying onto double envelopes). Any artefacts (1 = no artefact, 2 = presence of artefact less than 0.5 cm wide, and 3 = presence of artefact larger than 0.5 cm wide) on the 12 acquired images were evaluated.
resultsArtefacts (score-3) occurred on the images of Group C-2 PSP plate after the 3rd exposure. According to the Kruskal-Wallis test the difference between the artefact score of the four methods was found significant. Post-hoc comparisons showed the Group C artefact scores were higher than the others and the difference was significant. The total time of enveloping and disinfection processes for groups was; A = 6.30 min, B = 7.58 min, C = 5.48 min, and D = 7.14 min.
conclusionsRegardless of the number of envelopes, wiping with a tissue was less likely to cause artefacts, while spraying was reliable only when double envelopes were used. However, using a tissue and double envelopes, which are less risky in terms of artefact, causes time loss, difficulty in manipulation, environmental pollution and high cost.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.