Evidence map›Paper›PMID 35064786›Full record

ArticleNeuroradiology2022

Deep-learning 2.5-dimensional single-shot detector improves the performance of automated detection of brain metastases on contrast-enhanced CT.

Hidemasa Takao, Shiori Amemiya, Shimpei Kato, Hiroshi Yamashita, Naoya Sakamoto, Osamu Abe

Abstract read
PubMed Publisher
In one paragraph

Article in Neuroradiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hidemasa TakaoDepartment of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan. takaoh-tky@umin.ac.jp.ORCID http://orcid.org/0000-0001-7570-924X
Shiori AmemiyaDepartment of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Shimpei KatoDepartment of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Hiroshi YamashitaDepartment of Radiology, Teikyo University Hospital, Mizonokuchi, 5-1-1 Futago, Takatsu-ku, Kawasaki, Kanagawa, 213-8507, Japan.
Naoya SakamotoDepartment of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Osamu AbeDepartment of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aims to develop a 2.5-dimensional (2.5D) deep-learning, object detection model for the automated detection of brain metastases, into which three consecutive slices were fed as the input for the prediction in the central slice, and to compare its performance with that of an ordinary 2-dimensional (2D) model.

methodsWe analyzed 696 brain metastases on 127 contrast-enhanced computed tomography (CT) scans from 127 patients with brain metastases. The scans were randomly divided into training (n = 79), validation (n = 18), and test (n = 30) datasets. Single-shot detector (SSD) models with a feature fusion module were constructed, trained, and compared using the lesion-based sensitivity, positive predictive value (PPV), and the number of false positives per patient at a confidence threshold of 50%.

resultsThe 2.5D SSD model had a significantly higher PPV (t test, p < 0.001) and a significantly smaller number of false positives (t test, p < 0.001). The sensitivities of the 2D and 2.5D models were 88.1% (95% confidence interval [CI], 86.6-89.6%) and 88.7% (95% CI, 87.3-90.1%), respectively. The corresponding PPVs were 39.0% (95% CI, 36.5-41.4%) and 58.9% (95% CI, 55.2-62.7%), respectively. The numbers of false positives per patient were 11.9 (95% CI, 10.7-13.2) and 4.9 (95% CI, 4.2-5.7), respectively.

conclusionOur results indicate that 2.5D deep-learning, object detection models, which use information about the continuity between adjacent slices, may reduce false positives and improve the performance of automated detection of brain metastases compared with ordinary 2D models.

Indexed as

Brain NeoplasmsDeep LearningHumansTomography, X-Ray ComputedBrain metastasisBrain neoplasmsComputer-aided detectionDeep learningSingle-shot detectors

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.