Evidence map›Paper›PMID 35064371›Full record

ArticleJournal of digital imaging2022

Subcutaneous Low-Density Foreign Bodies Detection via Grating-Based Multimodal X-ray Imaging.

Meifang Yin, Mingzhou Yuan, Kai Deng, Jing Li, Guangya Zhang, Jiayuan Zhu, Weiping Xie, Jun Wu

Open access · hybridAbstract read
In one paragraph

Article in Journal of digital imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Meifang Yin *Department of Burn and Plastic Surgery, Department of Wound Repair, Shenzhen Institute of Translational Medicine, The First Affiliated Hospital of Shenzhen University, Second People's Hospital, ShenzhenShenzhen, 518035, China.
Mingzhou Yuan *Department of Burn Surgery, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China.
Kai DengInstitute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang, 621999, China.
Jing LiInstitute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang, 621999, China.
Guangya ZhangInstitute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang, 621999, China.
Jiayuan ZhuDepartment of Burn Surgery, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China.
Weiping XieInstitute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang, 621999, China. wpxie88@126.com.
Jun WuDepartment of Burn and Plastic Surgery, Department of Wound Repair, Shenzhen Institute of Translational Medicine, The First Affiliated Hospital of Shenzhen University, Second People's Hospital, ShenzhenShenzhen, 518035, China. junwupro@126.com.ORCID 0000-0002-4997-1970
Chinese Academy of Engineering · CNShenzhen Second People's Hospital · CNSun Yat-sen University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Detecting low-density foreign bodies within soft tissues still stands for a serious challenge. Grating-based multimodal X-ray imaging typically has low hardware requirements while simultaneously providing three kinds of imaging information, i.e., absorption, phase-contrast, and dark-field. We aimed to explore the capacity of grating-based multimodal X-ray imaging technology for detecting common foreign bodies within subcutaneous tissues, and to assess the advantages as well as disadvantages of the three kinds of images obtained via grating-based X-ray multimodal technology in relation to diverse kinds of foreign bodies within different tissues. In this study, metal, glass, wood, plastic, graphite, and ceramic foreign bodies were injected into chunks of the pig adipose tissue and chicken thigh muscles. Next, a grating-based multimodal X-ray imaging device developed in our laboratory was used to detect the above foreign bodies within the adipose and muscle tissues. Our results show that grating-based multimodal X-ray imaging clearly revealed the subcutaneous foreign bodies within the adipose and muscle tissues by acquiring complementary absorption, phase-contrast, and dark-field imaging data in a single shot. Grating-based multimodal X-ray imaging has an exciting potential to detect foreign bodies underneath the epidermis.

Indexed as

Foreign BodiesSubcutaneous TissueAnimalsHumansRadiographySwineX-RaysDark-field imagingGrating-based multimodal X-ray imagingLow-density foreign bodiesPhase-contrast imagingSoft tissue

Identifiers

PMID35064371
PMCPMC8921381
OpenAlexW4207072132

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.