Improvement in Strain Sensor Stability by Adapting the Metal Contact Layer.

Ji-Yeon Choy, Eun-Bee Jo, Chang-Joo Yim, Hae-Kyung Youi, Jung-Hoon Hwang, Jun-Ho Lee, Hyun-Seok Kim

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ji-Yeon ChoyDivision of Electronics and Electrical Engineering, Dongguk University, Seoul 04620, Korea.ORCID 0000-0001-9837-0912
Eun-Bee JoDivision of Electronics and Electrical Engineering, Dongguk University, Seoul 04620, Korea.ORCID 0000-0002-1925-9763
Chang-Joo YimDivision of Electronics and Electrical Engineering, Dongguk University, Seoul 04620, Korea.
Hae-Kyung YouiDivision of Electronics and Electrical Engineering, Dongguk University, Seoul 04620, Korea.ORCID 0000-0003-2155-5999
Jung-Hoon HwangDivision of Electronics and Electrical Engineering, Dongguk University, Seoul 04620, Korea.ORCID 0000-0002-2778-1893
Jun-Ho LeeDivision of Electronics and Electrical Engineering, Dongguk University, Seoul 04620, Korea.
Hyun-Seok KimDivision of Electronics and Electrical Engineering, Dongguk University, Seoul 04620, Korea.ORCID 0000-0003-1127-5766

Funding

National Research Foundation of Korea 2019R1A2C2086747
6 · The paper itself

Abstract

Research on stretchable strain sensors is actively conducted due to increasing interest in wearable devices. However, typical studies have focused on improving the elasticity of the electrode. Therefore, methods of directly connecting wire or attaching conductive tape to materials to detect deformation have been used to evaluate the performance of strain sensors. Polyaniline (PANI), a p-type semiconductive polymer, has been widely used for stretchable electrodes. However, conventional procedures have limitations in determining an appropriate metal for ohmic contact with PANI. Materials that are generally used for connection with PANI form an undesirable metal-semiconductor junction and have significant contact resistance. Hence, they degrade sensor performance. This study secured ohmic contact by adapting Au thin film as the metal contact layer (the MCL), with lower contact resistance and a larger work function than PANI. Additionally, we presented a buffer layer using hard polydimethylsiloxane (PDMS) and structured it into a dumbbell shape to protect the metal from deformation. As a result, we enhanced steadiness and repeatability up to 50% strain by comparing the gauge factors and the relative resistance changes. Consequently, adapting structural methods (the MCL and the dumbbell shape) to a device can result in strain sensors with promising stability, as well as high stretchability.

Indexed as

PDMSpolyanilinestrain sensorstretchable sensorwearable device

Identifiers

PMID35062593
PMCPMC8778142

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.