ArticleSensors (Basel, Switzerland)2022
Carbon Black/PDMS Based Flexible Capacitive Tactile Sensor for Multi-Directional Force Sensing.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 64 citations in OpenAlex.
- Tunable Plug-and-Play Meta-Nanogenerator Materials for Multi-Range Force Measurements.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- Double-Chamber Underwater Thruster Diaphragm with Flexible Displacement Detection Function.ACS omega · 2024Article
- Advancements and Applications of Micro and Nanostructured Capacitive Sensors: A Review.Sensors and actuators. A, Physical · 2024Article
- Design and Validation of Single-Axis 3D-Printed Force Sensor Based on Three Nested Flexible Rings.Sensors (Basel, Switzerland) · 2024Article
- Flexible Three-Dimensional Force Tactile Sensor Based on Velostat Piezoresistive Films.Micromachines · 2024Article
- A high sensitivity, low cost and fully decoupled multi-axis capacitive tactile force sensor for robotic surgical systems.PloS one · 2024Article
- Rational Design of Flexible Mechanical Force Sensors for Healthcare and Diagnosis.Materials (Basel, Switzerland) · 2023Review
- Composites Based on Cotton Microfibers Impregnated with Magnetic Liquid for Magneto-Tactile Sensors.Materials (Basel, Switzerland) · 2023Article
- Article
- Recent Progress of Biomimetic Tactile Sensing Technology Based on Magnetic Sensors.Biosensors · 2022Review
- Batch Fabrication of a Polydimethylsiloxane Based Stretchable Capacitive Strain Gauge Sensor for Orthopedics.Polymers · 2022Article
- Liquid Metal Patterned Stretchable and Soft Capacitive Sensor with Enhanced Dielectric Property Enabled by Graphite Nanofiber Fillers.Polymers · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
Abstract
Flexible sensing tends to be widely exploited in the process of human-computer interactions of intelligent robots for its contact compliance and environmental adaptability. A novel flexible capacitive tactile sensor was proposed for multi-directional force sensing, which is based on carbon black/polydimethylsiloxane (PDMS) composite dielectric layer and upper and lower electrodes of carbon nanotubes/polydimethylsiloxane (CNTs/PDMS) composite layer. By changing the ratio of carbon black, the resolution of carbon black/PDMS composite layer increases at 4 wt%, and then decreases, which was explained according to the percolation theory of the conductive particles in the polymer matrix. Mathematical model of force and capacitance variance was established, which can be used to predict the value of the applied force. Then, the prototype with carbon black/PDMS composite dielectric layer was fabricated and characterized. SEM observation was conducted and a ratio was introduced in the composites material design. It was concluded that the resolution of carbon sensor can reach 0.1 N within 50 N in normal direction and 0.2 N in 0-10 N in tangential direction with good stability. Finally, the multi-directional force results were obtained. Compared with the individual directional force results, the output capacitance value of multi-directional force was lower, which indicated the amplitude decrease in capacity change in the normal and tangential direction. This might be caused by the deformation distribution in the normal and tangential direction under multi-directional force.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.