ArticleSensors (Basel, Switzerland)2022
Dynamic Noise Reduction with Deep Residual Shrinkage Networks for Online Fault Classification.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Fault signals in high-voltage (HV) power plant assets are captured using the electromagnetic interference (EMI) technique. The extracted EMI signals are taken under different conditions, introducing varying noise levels to the signals. The aim of this work is to address the varying noise levels found in captured EMI fault signals, using a deep-residual-shrinkage-network (DRSN) that implements shrinkage methods with learned thresholds to carry out de-noising for classification, along with a time-frequency signal decomposition method for feature engineering of raw time-series signals. The approach will be to train and validate several alternative DRSN architectures with previously expertly labeled EMI fault signals, with architectures then being tested on previously unseen data, the signals used will firstly be de-noised and a controlled amount of noise will be added to the signals at various levels. DRSN architectures are assessed based on their testing accuracy in the varying controlled noise levels. Results show DRSN architectures using the newly proposed residual-shrinkage-building-unit-2 (RSBU-2) to outperform the residual-shrinkage-building-unit-1 (RSBU-1) architectures in low signal-to-noise ratios. The findings show that implementing thresholding methods in noise environments provides attractive results and their methods prove to work well with real-world EMI fault signals, proving them to be sufficient for real-world EMI fault classification and condition monitoring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.