Evidence map›Paper›PMID 35061781›Full record

ArticlePloS one2022

Validation of the Perception Neuron system for full-body motion capture.

Corliss Zhi Yi Choo, Jia Yi Chow, John Komar

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 2 pooled it
8.8field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 2 syntheses or guidelines pooled it, 48 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Corliss Zhi Yi ChooPhysical Education and Sports Science, National Institute of Education, Nanyang Technological University, Singapore, Singapore.ORCID 0000-0001-6832-6283
Jia Yi ChowPhysical Education and Sports Science, National Institute of Education, Nanyang Technological University, Singapore, Singapore.
John KomarPhysical Education and Sports Science, National Institute of Education, Nanyang Technological University, Singapore, Singapore.
Nanyang Technological University · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recent advancements in Inertial Measurement Units (IMUs) offers the possibility of its use as a cost effective and portable alternative to traditional optoelectronic motion capture systems in analyzing biomechanical performance. One such commercially available IMU is the Perception Neuron motion capture system (PNS). The accuracy of the PNS had been tested and was reported to be a valid method for assessing the upper body range of motion to within 5° RMSE. However, testing of the PNS was limited to upper body motion involving functional movement within a single plane. Therefore, the purpose of this study is to further validate the Perception Neuron system with reference to a conventional optoelectronic motion capture system (VICON) through the use of dynamic movements (e.g., walking, jogging and a multi-articular sports movement with object manipulation) and to determine its feasibility through full-body kinematic analysis. Validation was evaluated using Pearson's R correlation, RMSE and Bland-Altman estimates. Present findings suggest that the PNS performed well against the VICON motion analysis system with most joint angles reporting a RMSE of < 4° and strong average Pearson's R correlation of 0.85, with the exception of the shoulder abduction/adduction where RMSE was larger and Pearson's R correlation at a moderate level. Bland-Altman analysis revealed that most joint angles across the different movements had a mean bias of less than 10°, except for the shoulder abduction/adduction and elbow flexion/extension measurements. It was concluded that the PNS may not be the best substitute for traditional motion analysis technology if there is a need to replicate raw joint angles. However, there was adequate sensitivity to measure changes in joint angles and would be suitable when normalized joint angles are compared and the focus of analysis is to identify changes in movement patterns.

Indexed as

Wearable Electronic DevicesAdultBiomechanical PhenomenaFemaleHumansImaging, Three-DimensionalMaleMotionMovementOptical DevicesRange of Motion, ArticularReproducibility of Results

Identifiers

PMID35061781
PMCPMC8782534
OpenAlexW4206743397

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.