Evidence map›Paper›PMID 35059804›Full record

ArticleEuropean radiology2022

Diagnostic validation of a deep learning nodule detection algorithm in low-dose chest CT: determination of optimized dose thresholds in a virtual screening scenario.

Alan A Peters, Adrian T Huber, Verena C Obmann, Johannes T Heverhagen, Andreas Christe, Lukas Ebner

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Alan A PetersDepartment of Diagnostic, Interventional and Pediatric Radiology (DIPR), Bern University Hospital, University of Bern, Inselspital Bern, 3010, Switzerland. alan.peters@insel.ch.
Adrian T HuberDepartment of Diagnostic, Interventional and Pediatric Radiology (DIPR), Bern University Hospital, University of Bern, Inselspital Bern, 3010, Switzerland.
Verena C ObmannDepartment of Diagnostic, Interventional and Pediatric Radiology (DIPR), Bern University Hospital, University of Bern, Inselspital Bern, 3010, Switzerland.
Johannes T HeverhagenDepartment of Diagnostic, Interventional and Pediatric Radiology (DIPR), Bern University Hospital, University of Bern, Inselspital Bern, 3010, Switzerland.
Andreas ChristeDepartment of Diagnostic, Interventional and Pediatric Radiology (DIPR), Bern University Hospital, University of Bern, Inselspital Bern, 3010, Switzerland.
Lukas EbnerDepartment of Diagnostic, Interventional and Pediatric Radiology (DIPR), Bern University Hospital, University of Bern, Inselspital Bern, 3010, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study was conducted to evaluate the effect of dose reduction on the performance of a deep learning (DL)-based computer-aided diagnosis (CAD) system regarding pulmonary nodule detection in a virtual screening scenario.

methodsSixty-eight anthropomorphic chest phantoms were equipped with 329 nodules (150 ground glass, 179 solid) with four sizes (5 mm, 8 mm, 10 mm, 12 mm) and scanned with nine tube voltage/current combinations. The examinations were analyzed by a commercially available DL-based CAD system. The results were compared by a comparison of proportions. Logistic regression was performed to evaluate the impact of tube voltage, tube current, nodule size, nodule density, and nodule location.

resultsThe combination with the lowest effective dose (E) and unimpaired detection rate was 80 kV/50 mAs (sensitivity: 97.9%, mean false-positive rate (FPR): 1.9, mean CTDIvol: 1.2 ± 0.4 mGy, mean E: 0.66 mSv). Logistic regression revealed that tube voltage and current had the greatest impact on the detection rate, while nodule size and density had no significant influence.

conclusionsThe optimal tube voltage/current combination proposed in this study (80 kV/50 mAs) is comparable to the proposed combinations in similar studies, which mostly dealt with conventional CAD software. Modification of tube voltage and tube current has a significant impact on the performance of DL-based CAD software in pulmonary nodule detection regardless of their size and composition. KEY POINTS: • Modification of tube voltage and tube current has a significant impact on the performance of deep learning-based CAD software. • Nodule size and composition have no significant impact on the software's performance. • The optimal tube voltage/current combination for the examined software is 80 kV/50 mAs.

Indexed as

Deep LearningLung NeoplasmsSolitary Pulmonary NoduleAlgorithmsHumansRadiation DosageRadiographic Image Interpretation, Computer-AssistedSensitivity and SpecificityTomography, X-Ray ComputedArtificial intelligenceComputer-assisted diagnosisDeep learningLung neoplasmsRadiographic phantoms

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.