Evidence map›Paper›PMID 35059544›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2021

Improvement of Spatial Resolution with Iterative PET Reconstruction using UltraFast TOF.

Maxime Toussaint, Roger Lecomte, Jean-Pierre Dussault

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Time-of-Flight Requirements to Mitigate Blurring Induced by Annihilation Photon Acollinearity.IEEE transactions on radiation and plasma medical sciences · 2026
    Article
  3. Biodistribution studies ofApplied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2025
    Article
  4. Article
  5. Article
  6. Monte Carlo methods for medical imaging research.Biomedical engineering letters · 2024
    Review
  7. Article
  8. Image Reconstruction Analysis for Positron Emission Tomography With Heterostructured Scintillators.IEEE transactions on radiation and plasma medical sciences · 2023
    Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Maxime ToussaintDepartment of Computer Science, Université de Sherbrooke, Sherbrooke, QC, Canada.
Roger LecomteSherbrooke Molecular Imaging Center of CRCHUS and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, Sherbrooke, QC, Canada.
Jean-Pierre DussaultDepartment of Computer Science, Université de Sherbrooke, Sherbrooke, QC, Canada.

Funding

Ultra High Resolution Brain PET Scanner for in-vivo Autoradiography ImagingU01EB027003 · NIBIB · YALE UNIVERSITY · PI EL FAKHRI, GEORGES, FONTAINE, RÉJEAN · 2018 to 2022
$4.6M
NIBIB NIH HHS U01 EB027003
6 · The paper itself

Abstract

The impact of Time-of-Flight (TOF) on positron emission tomography (PET) spatial resolution is generally considered negligible. In this work, a two-step approach based on simulations of two-dimensional scanner configurations is taken to show that ultra-fast TOF has the potential to overcome the limitation induced by the physical size of detectors on spatial resolution. An estimation of the lower bound on spatial resolution using point sources is provided, followed by a qualitative assessment of the resolution obtained using a Hot Spot phantom. The impact of detector width, TOF resolution and TOF binning on the achieved spatial resolution is also studied. While gain beyond the expected blur due to detector size is demonstrated, the detector size remains one limiting factor albeit less prominent. The dependence on acquisition statistics to reach the full potential of TOF-induced gain in spatial resolution is demonstrated. A simulated brain phantom acquired with a fictive three-dimensional PET scanner was qualitatively analyzed and structures smaller than the typical limit are clearly made visible by reconstructing the images with a ∼13-ps TOF resolution. A potential application of this feature of ultra-fast TOF would be the design of clinical PET scanners achieving spatial resolution beyond the current state-of-the-art.

Indexed as

Iterative reconstructionPositron Emission TomographySimulationSpatial resolutionTime-of-Flight

Identifiers

PMID35059544
PMCPMC8765719

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.