Evidence map›Paper›PMID 35057294›Full record

ArticleMaterials (Basel, Switzerland)2022

Biomechanical Analyses of Porous Designs of 3D-Printed Titanium Implant for Mandibular Segmental Osteotomy Defects.

Yen-Wen Shen, Yuen-Shan Tsai, Jui-Ting Hsu, Ming-You Shie, Heng-Li Huang, Lih-Jyh Fuh

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yen-Wen ShenSchool of Dentistry, China Medical University, Taichung 404, Taiwan.
Yuen-Shan TsaiSchool of Dentistry, China Medical University, Taichung 404, Taiwan.
Jui-Ting HsuSchool of Dentistry, China Medical University, Taichung 404, Taiwan.ORCID 0000-0002-5533-2059
Ming-You ShieSchool of Dentistry, China Medical University, Taichung 404, Taiwan.ORCID 0000-0002-0650-4344
Heng-Li HuangSchool of Dentistry, China Medical University, Taichung 404, Taiwan.ORCID 0000-0001-8014-8248
Lih-Jyh FuhSchool of Dentistry, China Medical University, Taichung 404, Taiwan.ORCID 0000-0003-3008-8165

Funding

China Medical University (Taiwan) CMU110-MF-103Ministry of Science and Technology (Taiwan) Most 109-2221-E-039-002-MY2
6 · The paper itself

Abstract

Clinically, a reconstruction plate can be used for the facial repair of patients with mandibular segmental defects, but it cannot restore their chewing function. The main purpose of this research is to design a new three-dimensionally (3D) printed porous titanium mandibular implant with both facial restoration and oral chewing function reconstruction. Its biomechanical properties were examined using both finite element analysis (FEA) and in vitro experiments. Cone beam computed tomography images of the mandible of a patient with oral cancer were selected as a reference to create 3D computational models of the bone and of the 3D-printed porous implant. The pores of the porous implant were circles or hexagons of 1 or 2 mm in size. A nonporous implant was fabricated as a control model. For the FEA, two chewing modes, namely right unilateral molar clench and right group function, were set as loading conditions. Regarding the boundary condition, the displacement of both condyles was fixed in all directions. For the in vitro experiments, an occlusal force (100 N) was applied to the abutment of the 3D-printed mandibular implants with and without porous designs as the loading condition. The porous mandibular implants withstood higher stress and strain than the nonporous mandibular implant, but all stress values were lower than the yield strength of Ti-6Al-4V (800 MPa). The strain value of the bone surrounding the mandibular implant was affected not only by the shape and size of the pores but also by the chewing mode. According to Frost's mechanostat theory of bone, higher bone strain under the porous implants might help maintain or improve bone quality and bone strength. The findings of this study serve as a biomechanical reference for the design of 3D-printed titanium mandibular implants and require confirmation through clinical investigations.

Indexed as

3D-printed porous titanium mandibular implantfinite element analysismandibular segmental defectpore shapepore sizestrainstrain gauge in vitro experimentstress

Identifiers

PMID35057294
PMCPMC8779878

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.