Evidence map›Paper›PMID 35056213›Full record

ArticleMicromachines2021

Rapid, Simple and Inexpensive Fabrication of Paper-Based Analytical Devices by Parafilm

Surasak Kasetsirikul, Kimberley Clack, Muhammad J A Shiddiky, Nam-Trung Nguyen

Abstract read
In one paragraph

Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Microfluidic Paper-based Device for Medicinal Diagnosis.Current topics in medicinal chemistry · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Surasak KasetsirikulQueensland Micro- and Nanotechnology Centre (QMNC), Griffith University, Nathan, QLD 4111, Australia.
Kimberley ClackQueensland Micro- and Nanotechnology Centre (QMNC), Griffith University, Nathan, QLD 4111, Australia.
Muhammad J A ShiddikyQueensland Micro- and Nanotechnology Centre (QMNC), Griffith University, Nathan, QLD 4111, Australia.
Nam-Trung NguyenQueensland Micro- and Nanotechnology Centre (QMNC), Griffith University, Nathan, QLD 4111, Australia.ORCID 0000-0003-3626-5361

Funding

Australian Research Council DP180100055
6 · The paper itself

Abstract

Paper-based analytical devices have been substantially developed in recent decades. Many fabrication techniques for paper-based analytical devices have been demonstrated and reported. Herein, we report a relatively rapid, simple, and inexpensive method for fabricating paper-based analytical devices using parafilm hot pressing. We studied and optimized the effect of the key fabrication parameters, namely pressure, temperature, and pressing time. We discerned the optimal conditions, including a pressure of 3.8 MPa, temperature of 80 °C, and 3 min of pressing time, with the smallest hydrophobic barrier size (821 µm) being governed by laminate mask and parafilm dispersal from pressure and heat. Physical and biochemical properties were evaluated to substantiate the paper functionality for analytical devices. The wicking speed in the fabricated paper strips was slightly lower than that of non-processed paper, resulting from a reduced paper pore size after hot pressing. A colorimetric immunological assay was performed to demonstrate the protein binding capacity of the paper-based device after exposure to pressure and heat from the fabrication. Moreover, mixing in a two-dimensional paper-based device and flowing in a three-dimensional counterpart were thoroughly investigated, demonstrating that the paper devices from this fabrication process are potentially applicable as analytical devices for biomolecule detection. Fast, easy, and inexpensive parafilm hot press fabrication presents an opportunity for researchers to develop paper-based analytical devices in resource-limited environments.

Indexed as

paper-based analytical devicespaperfluidicsparafilm

Identifiers

PMID35056213
PMCPMC8780184

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.