Evidence map›Paper›PMID 35056172›Full record

ArticleMicromachines2021

Coupled Finite Element-Finite Volume Multi-Physics Analysis of MEMS Electrothermal Actuators.

Thomas Sciberras, Marija Demicoli, Ivan Grech, Bertram Mallia, Pierluigi Mollicone, Nicholas Sammut

Abstract read
In one paragraph

Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Thomas SciberrasDepartment of Mechanical Engineering, Faculty of Engineering, University of Malta, MSD 2080 Msida, Malta.
Marija DemicoliInstitute for Sustainable Energy, University of Malta, MXK 1531 Marsaxlokk, Malta.
Ivan GrechDepartment of Microelectronics and Nanoelectronics, Faculty of Information and Communications Technology, University of Malta, MSD 2080 Msida, Malta.
Bertram MalliaDepartment of Metallurgy and Materials Engineering, Faculty of Engineering, University of Malta, MSD 2080 Msida, Malta.ORCID 0000-0002-4719-0855
Pierluigi MolliconeDepartment of Mechanical Engineering, Faculty of Engineering, University of Malta, MSD 2080 Msida, Malta.ORCID 0000-0002-4234-0754
Nicholas SammutDepartment of Microelectronics and Nanoelectronics, Faculty of Information and Communications Technology, University of Malta, MSD 2080 Msida, Malta.ORCID 0000-0001-7679-604X

Funding

"Setting up of transdisciplinary research and knowledge exchange (TRAKE) complex at the University of Malta (ERDF.01.124)" which is being co-financed through the European Union through the European Regional Development Fund 2014 - 2020. www.eufunds.gov.mt N/A
6 · The paper itself

Abstract

Microelectromechanical systems (MEMS) are the instruments of choice for high-precision manipulation and sensing processes at the microscale. They are, therefore, a subject of interest in many leading industrial and academic research sectors owing to their superior potential in applications requiring extreme precision, as well as in their use as a scalable device. Certain applications tend to require a MEMS device to function with low operational temperatures, as well as within fully immersed conditions in various media and with different flow parameters. This study made use of a V-shaped electrothermal actuator to demonstrate a novel, state-of-the-art numerical methodology with a two-way coupled analysis. This methodology included the effects of fluid-structure interaction between the MEMS device and its surrounding fluid and may be used by MEMS design engineers and analysts at the design stages of their devices for a more robust product. Throughout this study, a thermal-electric finite element model was strongly coupled to a finite volume model to incorporate the spatially varying cooling effects of the surrounding fluid (still air) onto the V-shaped electrothermal device during steady-state operation. The methodology was compared to already established and accepted analysis methods for MEMS electrothermal actuators in still air. The maximum device temperatures for input voltages ranging from 0 V to 10 V were assessed. During the postprocessing routine of the two-way electrothermal actuator coupled analysis, a spatially-varying heat transfer coefficient was evident, the magnitude of which was orders of magnitude larger than what is typically applied to macro-objects operating in similar environmental conditions. The latter phenomenon was correlated with similar findings in the literature.

Indexed as

convectionelectrothermal actuator (ETA)finite elementfinite volumefluid–structure interactionmicroelectromechanical systems (MEMS)multi-physicsnumerical analysisV-shaped ETA

Identifiers

PMID35056172
PMCPMC8781855

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.