Evidence map›Paper›PMID 35054332›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Ultrasound Imaging of Acquired Myometrial Pseudoaneurysm: The Role of Manipulators as an Unusual Cause during Laparoscopic Surgery.

Francesca Buonomo, Clarice de Almeida Fiorillo, Danilo Oliveira de Souza, Fabio Pozzi Mucelli, Stefania Biffi, Federico Romano, Giovanni Di Lorenzo, Sofia Bussolaro, Giuseppe Ricci

Open access · goldAbstract readCase Reports
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 100% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Francesca BuonomoInstitute for Maternal and Child Health, I.R.C.C.S. Burlo Garofolo, 34137 Trieste, Italy.ORCID 0000-0002-6587-2622
Clarice de Almeida FiorilloInstitute for Maternal and Child Health, I.R.C.C.S. Burlo Garofolo, 34137 Trieste, Italy.
Danilo Oliveira de SouzaELETTRA Sincrotrone Trieste S.C.p.A., S.S. 14 Km 163.5, Basovizza, 34149 Trieste, Italy.ORCID 0000-0002-6086-7488
Fabio Pozzi MucelliDepartment of Diagnostic and Interventional Radiology, Cattinara Hospital, 34149 Trieste, Italy.
Stefania BiffiInstitute for Maternal and Child Health, I.R.C.C.S. Burlo Garofolo, 34137 Trieste, Italy.
Federico RomanoInstitute for Maternal and Child Health, I.R.C.C.S. Burlo Garofolo, 34137 Trieste, Italy.ORCID 0000-0003-2157-8330
Giovanni Di LorenzoInstitute for Maternal and Child Health, I.R.C.C.S. Burlo Garofolo, 34137 Trieste, Italy.
Sofia BussolaroDepartment of Medical, Surgical and Health Science, University of Trieste, 34127 Trieste, Italy.ORCID 0000-0002-0273-5700
Giuseppe RicciInstitute for Maternal and Child Health, I.R.C.C.S. Burlo Garofolo, 34137 Trieste, Italy.ORCID 0000-0002-8031-1102
IRCCS Materno Infantile Burlo Garofolo · ITUniversity of Trieste · ITElettra-Sincrotrone Trieste S.C.p.A. · ITOspedale di Cattinara · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An acquired uterine artery myometrial pseudoaneurysm can occur due to inflammation, trauma, or iatrogenic causes, such as surgical procedures, and can lead to profuse bleeding. The efficacy of uterine manipulators in gynecological surgery, particularly as a cause of a pseudoaneurysm, has been poorly discussed in the literature. In this paper, we discuss a case of a 39-year-old woman with profuse uterine bleeding that occurred seven days after operative laparoscopic surgery for endometriosis. The color Doppler ultrasound better evoked the arterial-like turbulent blood flow inside this cavity. These sonographic features were highly suggestive of uterine artery pseudoaneurysm, presumably related to a secondary trauma caused by the manipulator. The diagnosis was subsequently re-confirmed by angiography, and the patient was treated conservatively with uterine artery embolization. Ultrasound has been shown to be a valuable and safe tool for imaging pseudoaneurysm and guiding subsequent interventional procedures. Accordingly, we briefly review the most suitable manipulators used in benign gynecological surgeries to verify if the different types in use can guide the surgeon towards the correct choice according to surgical needs and thus prevent potentially dangerous trauma.

Indexed as

computed tomographydimensionmagnetic resonanceultrasounduterine artery pseudoaneurysm

Identifiers

PMID35054332
PMCPMC8774433
OpenAlexW4205388748

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.