Evidence map›Paper›PMID 35054331›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Development and Verification of an Adjustment Factor for Determining the Axial Length Using Optical Biometry in Silicone Oil-Filled Eyes.

Gerd U Auffarth, Tadas Naujokaitis, Louise Blöck, Anna Daghbashyan, Jan Meis, Victor A Augustin, Ramin Khoramnia, Timur M Yildirim

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Gerd U AuffarthInternational Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany.ORCID 0000-0002-6927-5251
Tadas NaujokaitisInternational Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany.
Louise BlöckInternational Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany.
Anna DaghbashyanInternational Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany.
Jan MeisInstitute of Medical Biometry, University of Heidelberg, 69120 Heidelberg, Germany.ORCID 0000-0001-5407-7220
Victor A AugustinInternational Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany.
Ramin KhoramniaInternational Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany.ORCID 0000-0002-6237-7773
Timur M YildirimInternational Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany.
Heidelberg University · DE

Funding

Heidelberg University N/AKlaus Tschira Foundation N/A
6 · The paper itself

Abstract

The aim of this prospective clinical study was to establish and verify an adaptation for axial length (AL) measurement in silicone oil (SO)-filled pseudophakic eyes with a Scheimpflug and partial coherence interferometry (PCI)-based biometer. The AL was measured with a Pentacam AXL (OCULUS Optikgeräte GmbH, Wetzler, Germany) and IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany). The coefficients of variation (CoV) and the mean systematic difference (95% confidence interval (CI)) between the devices were calculated. After implementing a setting for measuring AL in tamponaded eyes with a Pentacam based on data of 29 eyes, another 12 eyes were examined for verification. The mean AL obtained with the Pentacam was 25.53 ± 1.94 mm (range: 21.70 to 30.76 mm), and with IOLMaster, 24.73 ± 1.97 mm (ranged 20.84 to 29.92 mm), resulting in a mean offset of 0.80 ± 0.08 mm (95% CI: 0.77, 0.83 mm),

Indexed as

ocular biometryoptical coherence tomographyoptical diagnosispartial coherence interferometryrefractive outcomeretinal diseaseScheimpflug imagingtreatment options

Identifiers

PMID35054331
PMCPMC8775324
OpenAlexW4205442080

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.