Evidence map›Paper›PMID 35052339›Full record

ArticleHealthcare (Basel, Switzerland)2022

Diagnostic Performance of a Deep Learning Model Deployed at a National COVID-19 Screening Facility for Detection of Pneumonia on Frontal Chest Radiographs.

Jordan Z T Sim, Yong-Han Ting, Yuan Tang, Yangqin Feng, Xiaofeng Lei, Xiaohong Wang, Wen-Xiang Chen, Su Huang, Sum-Thai Wong, Zhongkang Lu and 5 more

Open access · goldAbstract read
In one paragraph

Article in Healthcare (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 3 institutions in 1 country.

Jordan Z T SimDepartment of Diagnostic Radiology, Tan Tock Seng Hospital, 11, Jalan Tan Tock Seng, Singapore 308433, Singapore.ORCID 0000-0002-4164-1643
Yong-Han TingDepartment of Diagnostic Radiology, Tan Tock Seng Hospital, 11, Jalan Tan Tock Seng, Singapore 308433, Singapore.ORCID 0000-0002-8682-9914
Yuan TangHealthcare-MedTech Division & Visual Intelligence Department, Institute for Infocomm Research, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Yangqin FengInstitute of High Performance Computing, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Xiaofeng LeiInstitute of High Performance Computing, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Xiaohong WangHealthcare-MedTech Division & Visual Intelligence Department, Institute for Infocomm Research, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Wen-Xiang ChenDepartment of Diagnostic Radiology, Tan Tock Seng Hospital, 11, Jalan Tan Tock Seng, Singapore 308433, Singapore.
Su HuangHealthcare-MedTech Division & Visual Intelligence Department, Institute for Infocomm Research, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Sum-Thai WongInstitute of High Performance Computing, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Zhongkang LuHealthcare-MedTech Division & Visual Intelligence Department, Institute for Infocomm Research, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Yingnan CuiInstitute of High Performance Computing, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Soo-Kng TeoInstitute of High Performance Computing, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Xin-Xing XuInstitute of High Performance Computing, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Wei-Min HuangHealthcare-MedTech Division & Visual Intelligence Department, Institute for Infocomm Research, A*STAR, 1 Fusionopolis Way, Singapore 138632, Singapore.
Cher-Heng TanDepartment of Diagnostic Radiology, Tan Tock Seng Hospital, 11, Jalan Tan Tock Seng, Singapore 308433, Singapore.
Agency for Science, Technology and Research · SGTan Tock Seng Hospital · SGNanyang Technological University · SG

Funding

Agency for Science, Technology and Research ACCL/19-GAP012-R20H
6 · The paper itself

Abstract

(1) Background: Chest radiographs are the mainstay of initial radiological investigation in this COVID-19 pandemic. A reliable and readily deployable artificial intelligence (AI) algorithm that detects pneumonia in COVID-19 suspects can be useful for screening or triage in a hospital setting. This study has a few objectives: first, to develop a model that accurately detects pneumonia in COVID-19 suspects; second, to assess its performance in a real-world clinical setting; and third, by integrating the model with the daily clinical workflow, to measure its impact on report turn-around time. (2) Methods: The model was developed from the NIH Chest-14 open-source dataset and fine-tuned using an internal dataset comprising more than 4000 CXRs acquired in our institution. Input from two senior radiologists provided the reference standard. The model was integrated into daily clinical workflow, prioritising abnormal CXRs for expedited reporting. Area under the receiver operating characteristic curve (AUC), F1 score, sensitivity, and specificity were calculated to characterise diagnostic performance. The average time taken by radiologists in reporting the CXRs was compared against the mean baseline time taken prior to implementation of the AI model. (3) Results: 9431 unique CXRs were included in the datasets, of which 1232 were ground truth-labelled positive for pneumonia. On the "live" dataset, the model achieved an AUC of 0.95 (95% confidence interval (CI): 0.92, 0.96) corresponding to a specificity of 97% (95% CI: 0.97, 0.98) and sensitivity of 79% (95% CI: 0.72, 0.84). No statistically significant degradation of diagnostic performance was encountered during clinical deployment, and report turn-around time was reduced by 22%. (4) Conclusion: In real-world clinical deployment, our model expedites reporting of pneumonia in COVID-19 suspects while preserving diagnostic performance without significant model drift.

Indexed as

artificialCOVID-19deepintelligencelearningmass chestpneumoniaX-ray

Identifiers

PMID35052339
PMCPMC8775598
OpenAlexW4205123636

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.