SynthesisArchives of orthopaedic and trauma surgery2022
Post-operative peri-prosthetic fracture rates following the use of cemented polished taper-slip stems for primary total hip arthroplasty: a systematic review.
Synthesis in Archives of orthopaedic and trauma surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 12 citations in OpenAlex.
- Maximizing stem body size may reduce the risk of postoperative periprosthetic fractures : an analysis of 2,757 CPT femoral components.Bone & joint open · 2026Article
- Management of periprosthetic fractures around cemented femoral stems: osteosynthesis and revision strategies.EFORT open reviews · 2026Review
- Review
- Fixation versus revision arthroplasty for Unified Classification System type B periprosthetic fractures around cemented polished tapered femoral components : a systematic review and meta-analysis.Bone & joint open · 2025Article
- The impact of cementing technique in polished taper fit hip stems : a modelling analysis of implant-cement interface.Bone & joint research · 2025Article
- Stem introducer designs and surgical technique play a significant role in achieving the optimal implant-cement interface.Bone & joint research · 2025Article
- Establishment and validation of a prognostic nomogram for periprosthetic femoral fracture after total hip replacement surgery.BMC musculoskeletal disorders · 2025Article
- Increased risk of periprosthetic fracture associated with decreased aseptic loosening in C-stem compared with the Charnley Elite Plus in primary total hip arthroplasty: a minimum 10-year follow-up study.BMC musculoskeletal disorders · 2025Article
- Outcomes of cemented taper slip versus composite beam femoral stems in total hip arthroplasty: A systematic review and meta-analysis.Qatar medical journal · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionPeri-prosthetic fractures (PPFs) are a serious complication of total hip arthroplasty (THA) associated with significant morbidity, mortality and re-operation similar to the rates seen following femoral neck fractures. When exploring the PPF rates around cemented stems, many studies combine the results of composite beam and taper-slip stems despite their different philosophies. This review looks specifically at PPFs with the use of cemented stems of the taper-slip philosophy to evaluate the demographics, PPF rate and fracture patterns in this patient cohort. MATERIALS AND
methodsA systematic search of Embase, Medline and CINAHL databases was performed to seek studies involving the use of cemented, polished, taper-slip stems, reporting on a rate of post-operative PPF and not involving patient cohorts that were exclusively hip fracture or revision arthroplasty.
results27 studies reported on 505 PPFs with an average time from primary operation to PPF of 71.2 months (2-301 months). The average age of patients who sustained PPFs was 70.6 years (53.5-82 years) and the majority were female (64.2%). The Vancouver B2 fracture type was most common (39.5%). Open reduction and internal fixation represented the management of choice in 61.2% of PPFs. There was a re-operation rate of 11.4%.
conclusionThis review suggests an association with being older and female, and a greater risk of PPFs secondary to low energy falls in cemented polished taper-slip stems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials