Evidence map›Paper›PMID 35048171›Full record

SynthesisArchives of orthopaedic and trauma surgery2022

Post-operative peri-prosthetic fracture rates following the use of cemented polished taper-slip stems for primary total hip arthroplasty: a systematic review.

Kwaku Baryeh, David H Sochart

Abstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Archives of orthopaedic and trauma surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Kwaku BaryehEducation Centre, West Middlesex University Hospital, Twickenham Road, Middlesex, TW7 6AF, UK. Kwaku.baryeh1@nhs.net.ORCID http://orcid.org/0000-0002-2807-1965
David H SochartThe Academic Surgical Unit, South West London Elective Orthopaedic Centre, Epsom General Hospital, Dorking Road, Epsom, KT18 7EG, UK.
Epsom Hospital · GBWest Middlesex University Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPeri-prosthetic fractures (PPFs) are a serious complication of total hip arthroplasty (THA) associated with significant morbidity, mortality and re-operation similar to the rates seen following femoral neck fractures. When exploring the PPF rates around cemented stems, many studies combine the results of composite beam and taper-slip stems despite their different philosophies. This review looks specifically at PPFs with the use of cemented stems of the taper-slip philosophy to evaluate the demographics, PPF rate and fracture patterns in this patient cohort. MATERIALS AND

methodsA systematic search of Embase, Medline and CINAHL databases was performed to seek studies involving the use of cemented, polished, taper-slip stems, reporting on a rate of post-operative PPF and not involving patient cohorts that were exclusively hip fracture or revision arthroplasty.

results27 studies reported on 505 PPFs with an average time from primary operation to PPF of 71.2 months (2-301 months). The average age of patients who sustained PPFs was 70.6 years (53.5-82 years) and the majority were female (64.2%). The Vancouver B2 fracture type was most common (39.5%). Open reduction and internal fixation represented the management of choice in 61.2% of PPFs. There was a re-operation rate of 11.4%.

conclusionThis review suggests an association with being older and female, and a greater risk of PPFs secondary to low energy falls in cemented polished taper-slip stems.

Indexed as

Arthroplasty, Replacement, HipFemoral FracturesHip ProsthesisPeriprosthetic FracturesAgedFemaleHumansMaleProsthesis DesignReoperationCemented femurPeri-prosthetic fracturePolished taper-slip stemTotal hip replacementVancouver classification

Identifiers

PMID35048171
OpenAlexW4205309609

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.