ArticlePloS one2022
Transforming and comparing data between standard SQUID and OPM-MEG systems.
Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed, 1 synthesis or guideline pooled it, 55 citations in OpenAlex.
- Global trends and knowledge structure of cardiovascular magnetocardiography research: a bibliometric analysis.Frontiers in medicine · 2026Pooled it
- Quantifying cerebellar signal detectability in MEG and EEG in epilepsy using anatomically informed source modeling.NeuroImage · 2026Article
- Neuromagnetism "On the Cheap": Evaluating a Combined Cylindrical Shield and Partial-Coverage OPM-MEG System for Detecting Sensorimotor Responses in Humans.Sensors (Basel, Switzerland) · 2026Article
- Optically pumped magnetometers enhance neuroimaging performance-An EEG, OPM, and SQUID-MEG study.iScience · 2026Article
- Progress in Clinical Magnetocardiography: The Contactless Breakthrough for Noninvasive Clinical Detection of Cardiac Ischemia Now Needs Worldwide Standardization.Sensors (Basel, Switzerland) · 2026Review
- Optimizing OPM-MEG Sensor Layouts Using the Sequential Selection Algorithm with Simulated Sources and Individual Anatomy.Sensors (Basel, Switzerland) · 2026Article
- Quantifying Cerebellar Signal Detectability in MEG and EEG in Epilepsy Using Anatomically Informed Source Modeling.bioRxiv : the preprint server for biology · 2026Article
- Automatic Removal of Physiological Artifacts in OPM-MEG: A Framework of Channel Attention Mechanism Based on Magnetic Reference Signal.Biosensors · 2025Article
- γ neuromodulations: unraveling biomarkers for neurological and psychiatric disorders.Military Medical Research · 2025Review
- Optimization of OPM-MEG Layouts with a Limited Number of Sensors.Sensors (Basel, Switzerland) · 2025Article
- Phantom-Based Approach for Comparing Conventional and Optically Pumped Magnetometer Magnetoencephalography Systems.Sensors (Basel, Switzerland) · 2025Article
- Anatomically Veridical On-Scalp Sensor Topographies.The European journal of neuroscience · 2025Article
- [Movable Array of Magnetoencephalography With Optically Pumped Magnetometers Effectively Captures Primary Auditory-Evoked Response Signals in Healthy Populations at Low Altitudes].Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition · 2024Article
- Decoding the Temporal Structures and Interactions of Multiple Face Dimensions Using Optically Pumped Magnetometer Magnetoencephalography (OPM-MEG).The Journal of neuroscience : the official journal of the Society for Neuroscience · 2024Article
- Applications of OPM-MEG for translational neuroscience: a perspective.Translational psychiatry · 2024Review
- Decoding N400m Evoked Component: A Tutorial on Multivariate Pattern Analysis for OP-MEG Data.Bioengineering (Basel, Switzerland) · 2024Article
- A simulation study: comparing independent component analysis and signal-space projection - source-informed reconstruction for rejecting muscle artifacts evoked by transcranial magnetic stimulation.Frontiers in human neuroscience · 2024Article
- Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG.Journal of neural engineering · 2023Article
- Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding.NeuroImage · 2023Article
- Improved Biomagnetic Signal-To-Noise Ratio and Source Localization Using Optically Pumped Magnetometers with Synthetic Gradiometers.Brain sciences · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Optically pumped magnetometers (OPMs) have recently become so sensitive that they are suitable for use in magnetoencephalography (MEG). These sensors solve operational problems of the current standard MEG, where superconducting quantum interference device (SQUID) gradiometers and magnetometers are being used. The main advantage of OPMs is that they do not require cryogenics for cooling. Therefore, they can be placed closer to the scalp and are much easier to use. Here, we measured auditory evoked fields (AEFs) with both SQUID- and OPM-based MEG systems for a group of subjects to better understand the usage of a limited sensor count OPM-MEG. We present a theoretical framework that transforms the within subject data and equivalent simulation data from one MEG system to the other. This approach works on the principle of solving the inverse problem with one system, and then using the forward model to calculate the magnetic fields expected for the other system. For the source reconstruction, we used a minimum norm estimate (MNE) of the current distribution. Two different volume conductor models were compared: the homogeneous conducting sphere and the three-shell model of the head. The transformation results are characterized by a relative error and cross-correlation between the measured and the estimated magnetic field maps of the AEFs. The results for both models are encouraging. Since some commercial OPMs measure multiple components of the magnetic field simultaneously, we additionally analyzed the effect of tangential field components. Overall, our dual-axis OPM-MEG with 15 sensors yields similar information to a 62-channel SQUID-MEG with its field of view restricted to the right hemisphere.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials