Trial reportJAMA surgery2022
Biologic vs Synthetic Mesh for Single-stage Repair of Contaminated Ventral Hernias: A Randomized Clinical Trial.
Trial report in JAMA surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02451176 (A Prospective Randomized Trial of Biologic Mesh Versus Synthetic Mesh for the Repair of Complex Ventral Hernias), which is not on this map. Cited by 96 papers, 12 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Prospective Randomized Trial of Biologic Mesh Versus Synthetic Mesh for the Repair of Complex Ventral Hernias
Who cites it
96 citing papers in PubMed, 12 syntheses or guidelines pooled it, 170 citations in OpenAlex.
- Complications after biosynthetic long-term absorbable mesh implantation for ventral hernia repair in clean and contaminated environments: a systematic review and meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2026Pooled it
- Frailty index as a predictive tool for poor outcomes after ventral hernia repair - systematic review and meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2026Pooled it
- Full-thickness skin and dermal grafts as abdominal wall augmentation in ventral hernia repairs - a systematic review.Hernia : the journal of hernias and abdominal wall surgery · 2026Pooled it
- Prophylactic mesh at stoma reversal reduces incisional hernia without increasing early complications: a systematic review and meta-analysis of randomised trials.Hernia : the journal of hernias and abdominal wall surgery · 2026Pooled it
- Cost-effectiveness of selective prophylactic mesh placement after stoma closure.Hernia : the journal of hernias and abdominal wall surgery · 2025Pooled it
- Synthetic vs. biologic mesh for abdominal wall reconstruction in contaminated surgical fields. A meta-analysis of randomized controlled trials and observational studies.Hernia : the journal of hernias and abdominal wall surgery · 2024Pooled it
- A systematic review and meta-analysis of randomized controlled trials for the management of ventral hernia: biologic versus synthetic mesh.Updates in surgery · 2024Pooled it
- The use of poly-4-hydroxybutyrate (P4HB, Phasix™) mesh in ventral hernia repair: a systematic review and meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2024Pooled it
- Spigelian hernias in the adult population: a systematic review of the literature.Langenbeck's archives of surgery · 2024Pooled it
- Ventral hernia repair using bioresorbable poly-4-hydroxybutyrate mesh in clean and contaminated surgical fields: a systematic review and meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2024Pooled it
- Mesh versus non-mesh for emergency groin hernia repair.The Cochrane database of systematic reviews · 2023Pooled it
- Synthetic Versus Biological Mesh in Ventral Hernia Repair and Abdominal Wall Reconstruction: A Systematic Review and Recommendations from Evidence-Based Medicine.World journal of surgery · 2023Pooled it
- Comparative Outcomes of Two Non-Crosslinked Porcine Acellular Dermal Matrices in Complex Abdominal Wall Reconstruction: A Randomized Controlled Trial and an Observational Cohort Study.World journal of surgery · 2026Trial
- Analysis of retromuscular drain output and postoperative outcomes for heavyweight versus mediumweight polypropylene mesh following open ventral hernia repair.Hernia : the journal of hernias and abdominal wall surgery · 2024Trial
- Synthetic mesh versus biological mesh to prevent incisional hernia after loop-ileostomy closure: a randomized feasibility trial.BMC surgery · 2023Trial
- The early outcomes of complex abdominal wall reconstruction with polyvinylidene (PVDF) mesh in the setting of active infection: a prospective series.Langenbeck's archives of surgery · 2022Trial
- Comparison of mesh infection management following ventral hernia repair with poly-4-hydroxybutyrate, synthetic, and biologic mesh: a retrospective review.Surgical endoscopy · 2026Article
- Comparative outcomes of bioabsorbable poly-4-hydroxybutyrate versus synthetic mesh in ventral hernia repair: A propensity-matched cohort study.Hernia : the journal of hernias and abdominal wall surgery · 2026Article
- Parastomal Hernia: Rethinking Prevention and Repair in Contemporary Colorectal Surgery.ANZ journal of surgery · 2026Article
- Experience of biological implants in thoracic surgery for soft tissue and chest wall reconstruction in clean and contaminated environments.Journal of thoracic disease · 2026Article
36 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Commented on by
- Commented on by
- Commented on by
Authors and funding
10 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
importanceBiologic mesh is widely used for reinforcing contaminated ventral hernia repairs; however, it is expensive and has been associated with high rates of long-term hernia recurrence. Synthetic mesh is a lower-cost alternative but its efficacy has not been rigorously studied in individuals with contaminated hernias.
objectiveTo determine whether synthetic mesh results in superior reduction in risk of hernia recurrence compared with biologic mesh during the single-stage repair of clean-contaminated and contaminated ventral hernias. DESIGN, SETTING, AND
participantsThis multicenter, single-blinded randomized clinical trial was conducted from December 2012 to April 2019 with a follow-up duration of 2 years. The trial was completed at 5 academic medical centers in the US with specialized units for abdominal wall reconstruction. A total of 253 adult patients with clean-contaminated or contaminated ventral hernias were enrolled in this trial. Follow-up was completed in April 2021.
interventionsRetromuscular synthetic or biologic mesh at the time of fascial closure. MAIN OUTCOMES AND MEASURES: The primary outcome was the superiority of synthetic mesh vs biologic mesh at reducing risk of hernia recurrence at 2 years based on intent-to-treat analysis. Secondary outcomes included mesh safety, defined as the rate of surgical site occurrence requiring a procedural intervention, and 30-day hospital direct costs and prosthetic costs.
resultsA total of 253 patients (median [IQR] age, 64 [55-70] years; 117 [46%] male) were randomized (126 to synthetic mesh and 127 to biologic mesh) and the follow-up rate was 92% at 2 years. Compared with biologic mesh, synthetic mesh significantly reduced the risk of hernia recurrence (hazard ratio, 0.31; 95% CI, 0.23-0.42; P < .001). The overall intent-to-treat hernia recurrence risk at 2 years was 13% (33 of 253 patients). Recurrence risk with biologic mesh was 20.5% (26 of 127 patients) and with synthetic mesh was 5.6% (7 of 126 patients), with an absolute risk reduction of 14.9% with the use of synthetic mesh (95% CI, -23.8% to -6.1%; P = .001). There was no significant difference in overall 2-year risk of surgical site occurrence requiring a procedural intervention between the groups (odds ratio, 1.22; 95% CI, 0.60-2.44; P = .58). Median (IQR) 30-day hospital direct costs were significantly greater in the biologic group vs the synthetic group ($44 936 [$35 877-$52 656] vs $17 289 [$14 643-$22 901], respectively; P < .001). There was also a significant difference in the price of the prosthetic device between the 2 groups (median [IQR] cost biologic, $21 539 [$20 285-$23 332] vs synthetic, $105 [$105-$118]; P < .001). CONCLUSIONS AND RELEVANCE: Synthetic mesh demonstrated superior 2-year hernia recurrence risk compared with biologic mesh in patients undergoing single-stage repair of contaminated ventral hernias, and both meshes demonstrated similar safety profiles. The price of biologic mesh was over 200 times that of synthetic mesh for these outcomes.
trial registrationClinicalTrials.gov Identifier: NCT02451176.