ArticleBioinformatics (Oxford, England)2022
ptairMS: real-time processing and analysis of PTR-TOF-MS data for biomarker discovery in exhaled breath.
Article in Bioinformatics (Oxford, England), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.
- Current data processing methods and reporting standards for untargeted analysis of volatile organic compounds using direct mass spectrometry: a systematic review.Metabolomics : Official journal of the Metabolomic Society · 2024Pooled it
- Sorbent-coated metal discs for time-integrated VOC sampling: A reproducible workflow coupled to SPME-GC/MS.MethodsX · 2026Article
- Soft ionization by chemical reaction in transfer-high-resolution mass spectrometry for clinical exhaled breath profiling.Analytical and bioanalytical chemistry · 2026Article
- Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling.Plant methods · 2026Article
- Metabolomic Approaches to Lung Function in Pediatric Asthma: A Narrative Review.Children (Basel, Switzerland) · 2026Review
- Prosystemin-derived signals: bridging leaf microbiome dynamics and defense activation.Environmental microbiome · 2026Article
- Rapid and noninvasive artificial intelligence-assisted diagnostic method for oral squamous cell carcinoma.NPJ digital medicine · 2026Article
- Combination of real-time and hyphenated mass spectrometry for improved characterisation of exhaled breath biomarkers in clinical research.Analytical and bioanalytical chemistry · 2024Article
- Enhanced real-time mass spectrometry breath analysis for the diagnosis of COVID-19.ERJ open research · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
motivationAnalysis of volatile organic compounds (VOCs) in exhaled breath by proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) is of increasing interest for real-time, non-invasive diagnosis, phenotyping and therapeutic drug monitoring in the clinics. However, there is currently a lack of methods and software tools for the processing of PTR-TOF-MS data from cohorts and suited for biomarker discovery studies.
resultsWe developed a comprehensive suite of algorithms that process raw data from patient acquisitions and generate the table of feature intensities. Notably, we included an innovative two-dimensional peak deconvolution model based on penalized splines signal regression for accurate estimation of the temporal profile and feature quantification, as well as a method to specifically select the VOCs from exhaled breath. The workflow was implemented as the ptairMS software, which contains a graphical interface to facilitate cohort management and data analysis. The approach was validated on both simulated and experimental datasets, and we showed that the sensitivity and specificity of the VOC detection reached 99% and 98.4%, respectively, and that the error of quantification was below 8.1% for concentrations down to 19 ppb. AVAILABILITY AND IMPLEMENTATION: The ptairMS software is publicly available as an R package on Bioconductor (doi: 10.18129/B9.bioc.ptairMS), as well as its companion experiment package ptairData (doi: 10.18129/B9.bioc.ptairData). SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.