ArticleJournal of diabetes science and technology2023
Development of a Novel Insulin Sensor for Clinical Decision-Making.
Article in Journal of diabetes science and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
backgroundClinical decision support systems that incorporate information from frequent insulin measurements to enhance individualized diabetes management remain an unmet goal. The development of a disposable insulin strip for fast decentralized point-of-care detection replacing the current centralized lab-based methods used in clinical practice would be highly desirable to improve the establishment of individual insulin absorption patterns and algorithm modeling processes.
methodsWe carried out the development and optimization of a novel decentralized disposable insulin electrochemical sensor focusing on obtaining high analytical and operational performance toward achieving a true point-of-care insulin testing device for clinical on-site application.
resultsOur novel insulin immunosensor demonstrated an attractive performance and efficient user-friendly operation by providing high sensitivity capability to detect endogenous and analog insulin with a limit of detection of 30.2 pM (4.3 µiU/mL), rapid time-to-result, stability toward remote site application, and scalable low-cost fabrication with an estimated cost-of-goods for disposable consumables of below $5, capable of near real-time insulin detection in a microliter (≤10 µL) sample droplet of undiluted serum within 30 minutes.
conclusionsThe results obtained in the optimization and characterization of our novel insulin sensor illustrate its suitability for its potential application in remote clinical environments for frequent insulin monitoring. Future work will test the insulin sensor in a clinical research setting to assess its efficacy in individuals with type 1 diabetes.