Evidence map›Paper›PMID 35042131›Full record

ArticleBiosensors & bioelectronics2022

Capacitive biosensor based on vertically paired electrodes for the detection of SARS-CoV-2.

Jun-Hee Park, Ga-Yeon Lee, Zhiquan Song, Ji-Hong Bong, Young Wook Chang, Sungbo Cho, Min-Jung Kang, Jae-Chul Pyun

Open access · greenAbstract read
In one paragraph

Article in Biosensors & bioelectronics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.6field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 36 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Capacitive immunosensor for COVID-19 diagnosis.Microelectronic engineering · 2023
    Article
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Jun-Hee ParkDepartment of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, South Korea.
Ga-Yeon LeeDepartment of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, South Korea; Electronic Convergence Division, Korea Institute of Ceramic Engineering and Technology (KICET), Jinju, 52851, South Korea.
Zhiquan SongDepartment of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, South Korea.
Ji-Hong BongDepartment of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, South Korea.
Young Wook ChangDepartment of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, South Korea.
Sungbo ChoDepartment of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do, 13120, South Korea.
Min-Jung KangKorea Institute of Science and Technology (KIST), Seoul, South Korea.
Jae-Chul PyunDepartment of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, South Korea. Electronic address: jcpyun@yonsei.ac.kr.
Yonsei University · KRGachon University · KRKorea Institute of Science and Technology · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Vertically paired electrodes (VPEs) with multiple electrode pairs were developed for the enhancement of capacitive measurements by optimizing the electrode gap and number of electrode pairs. The electrode was fabricated using a conductive polymer layer of PEDOT:PSS instead of Ag and Pt metal electrodes to increase the VPE fabrication yield because the PEDOT:PSS layer could be effectively etched using a reactive dry etching process. In this study, sensitivity enhancement was realized by decreasing the electrode gap and increasing the number of VPE electrode pairs. Such an increase in sensitivity according to the electrode gap and the number of electrode pairs was estimated using a model analyte for an immunoassay. Additionally, a computer simulation was performed using VPEs with different electrode gaps and numbers of VPE electrode pairs. Finally, VPEs with multiple electrode pairs were applied for SARS-CoV-2 nucleoprotein (NP) detection. The capacitive biosensor based on the VPE with immobilized anti-SARS-CoV-2 NP was applied for the specific detection of SARS-CoV-2 in viral cultures. Using viral cultures of SARS-CoV-2, SARS-CoV, MERS-CoV, and CoV-strain 229E, the limit of detection (LOD) was estimated to satisfy the cutoff value (dilution factor of 1/800) for the medical diagnosis of COVID-19, and the assay results from the capacitive biosensor were compared with commercial rapid kit based on a lateral flow immunoassay.

Indexed as

Biosensing TechniquesCOVID-19Computer SimulationElectrodesHumansSARS-CoV-2Sensitivity and SpecificityCapacitive biosensorImmunoassayNucleoprotein (NP)PEDOT:PSSSARS-CoV-2Vertically paired electrode

Identifiers

PMID35042131
PMCPMC8741629
OpenAlexW4206478876

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked