Beam properties within the momentum acceptance of a clinical gantry beamline for proton therapy.
Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- 3D magnetic field modeling and beam optics validation for a static gantry system.Radiological physics and technology · 2026Article
- Reduced beam time and distal linear energy transfer with mini-ridge filters in pencil beam scanning proton therapy.Physics and imaging in radiation oncology · 2026Article
- Towards ultra-fast treatments: large energy acceptance beam delivery systems and opportunities for proton beam therapy.Frontiers in oncology · 2026Review
- Comparative evaluation of static and dynamic 4D dose recalculations in pencil beam scanning proton therapy for oesophageal cancer.Physics and imaging in radiation oncology · 2026Article
- Optimization and fabrication of a novel 3D-printed variable density range modulation device for proton FLASH beams.Medical physics · 2025Article
- Operational Improvement of a Proton Therapy System From Reduced Energy Layer Switching Time.International journal of particle therapy · 2025Article
- Navigating the straits: realizing the potential of proton FLASH through physics advances and further pre-clinical characterization.Frontiers in oncology · 2024Review
- Increase of the transmission and emittance acceptance through a cyclotron-based proton therapy gantry.Medical physics · 2022Article
- Beam properties within the momentum acceptance of a clinical gantry beamline for proton therapy.Medical physics · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
purposeEnergy changes in pencil beam scanning proton therapy can be a limiting factor in delivery time, hence, limiting patient throughput and the effectiveness of motion mitigation techniques requiring fast irradiation. In this study, we investigate the feasibility of performing fast and continuous energy modulation within the momentum acceptance of a clinical beamline for proton therapy.
methodsThe alternative use of a local beam degrader at the gantry coupling point has been compared with a more common upstream regulation. Focusing on clinically relevant parameters, a complete beam properties characterization has been carried out. In particular, the acquired empirical data allowed to model and parametrize the errors in range and beam current to deliver clinical treatment plans.
resultsFor both options, the local and upstream degrader, depth-dose curves measured in water for off-momentum beams were only marginally distorted (γ(1%, 1 mm) > 90%) and the errors in the spot position were within the clinical tolerance, even though increasing at the boundaries of the investigated scan range. The impact on the beam size was limited for the upstream degrader, while dedicated strategies could be required to tackle the beam broadening through the local degrader. Range correction models were investigated for the upstream regulation. The impaired beam transport required a dedicated strategy for fine range control and compensation of beam intensity losses. Our current parameterization based on empirical data allowed energy modulation within acceptance with range errors (median 0.05 mm) and transmission (median -14%) compatible with clinical operation and remarkably low average 27 ms dead time for small energy changes. The technique, tested for the delivery of a skull glioma treatment, resulted in high gamma pass rates at 1%, 1 mm compared to conventional deliveries in experimental measurements with about 45% reduction of the energy switching time when regulation could be performed within acceptance.
conclusionsFast energy modulation within beamline acceptance has potential for clinical applications and, when realized with an upstream degrader, does not require modification in the beamline hardware, therefore, being potentially applicable in any running facility. Centers with slow energy switching time can particularly profit from such a technique for reducing dead time during treatment delivery.