Evidence map›Paper›PMID 35041132›Full record

ArticleInternational journal of computer assisted radiology and surgery2022

Cardiac X-ray image-based haptic guidance for robot-assisted coronary intervention: a feasibility study.

Abdullah Tahir, Hashim Iqbal, Muhammad Usman, Asim Ghaffar, Awais Hafeez

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 2 pooled it
0.3field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 syntheses or guidelines pooled it, 4 citations in OpenAlex.

  1. Tactile Feedback in Robot-Assisted Minimally Invasive Surgery: A Systematic Review.The international journal of medical robotics + computer assisted surgery : MRCAS · 2024
    Pooled it
  2. Pooled it
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Abdullah TahirDepartment of Mechatronics and Control Engineering, University of Engineering and Technology Lahore, Faisalabad Campus, Lahore, Pakistan.
Hashim IqbalDepartment of Mechatronics and Control Engineering, University of Engineering and Technology Lahore, Faisalabad Campus, Lahore, Pakistan.
Muhammad UsmanDepartment of Mechatronics and Control Engineering, University of Engineering and Technology Lahore, Faisalabad Campus, Lahore, Pakistan.
Asim GhaffarDepartment of Mechatronics and Control Engineering, University of Engineering and Technology Lahore, Faisalabad Campus, Lahore, Pakistan. asim.ghaffar@uet.edu.pk.
Awais HafeezDepartment of Mechatronics and Control Engineering, University of Engineering and Technology Lahore, Faisalabad Campus, Lahore, Pakistan.
University of Engineering and Technology Lahore · PK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEffective and efficient haptic guidance is desirable for tele-operated robotic surgery because it has a potential to enhance surgeon's skills, especially in coronary interventions where surgeon loses both an eye-hand coordination and a direct sight to the organ. This paper proposes a novel haptic guidance procedure-both kinesthetic and cutaneous, which solely depends upon X-ray images, for tele-robotic system that assists an efficient navigation of the guidewire towards the target location during a coronary intervention.

methodsProposed methodology requires cardiologists to draw virtual fixtures (VFs) on angiograms as a preoperative procedure. During an operation, these VFs direct the guidewire to the desired coronary vessel. For this, the position and orientation of guidewire tip are calculated with respect to VFs' anatomy, using image processing on the real-time 2D fluoroscopic images. The haptic feedbacks are then rendered on to the master device depending on the interaction with attractive and repulsive, guidance and forbidden region VFs.

resultsA feasibility study in the laboratory environment is performed by using a webcam as an image acquisition device and a phantom-based coronary vessel model. The subsequent statistical analysis shows that, on an average, a decrease of approx. 37% in task completion time is observed with haptic feedback. Moreover, haptic guidance is found effective for most difficult branch, whereas there is a minimal significance of such haptics for the easiest branch.

conclusionsThe proposed haptic guidance procedure may assist cardiologists for an efficient and effective guidewire navigation during a surgical procedure. The cutaneous haptics (vibration feedback) is found more helpful in coronary interventions compared with kinesthetic haptics (force feedback).

Indexed as

RoboticsRobotic Surgical ProceduresFeasibility StudiesFeedbackHaptic TechnologyHumansX-RaysCardiac interventionHaptic guidanceTele-operationVirtual fixturesX-ray images

Identifiers

PMID35041132
OpenAlexW4205772997

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.