Evidence map›Paper›PMID 35038062›Full record

ArticleMagma (New York, N.Y.)2022

Biopsy-based optimization and calibration of a signal-intensity-ratio-based MRI method (1.5 Tesla) in a dextran-iron loaded mini-pig model, enabling estimation of very high liver iron concentrations.

Peter D Jensen, Asbjørn H Nielsen, Carsten W Simonsen, Kenneth K Jensen, Martin Bøgsted, Anne B H Jensen, Benedict Kjaergaard

Open access · hybridAbstract read
In one paragraph

Article in Magma (New York, N.Y.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Peter D JensenDepartment of Hematology, University Hospital, Aalborg, Denmark. d222615@dadlnet.dk.ORCID http://orcid.org/0000-0003-3134-3973
Asbjørn H NielsenDepartment of the Built Environment, Aalborg University, Aalborg, Denmark.ORCID https://orcid.org/0000-0003-4464-8549
Carsten W SimonsenDepartment of Radiology, Imaging Research Unit, Aalborg University Hospital, Aalborg, Denmark.
Kenneth K JensenDepartment of Radiology, Imaging Research Unit, Aalborg University Hospital, Aalborg, Denmark.
Martin BøgstedDepartment of Hematology, University Hospital, Aalborg, Denmark.
Anne B H JensenThe Faculty of Medicine, Aalborg University, Aalborg, Denmark.
Benedict KjaergaardBiomedical Research Laboratory, Aalborg University Hospital, Aalborg, Denmark.
Aalborg University Hospital · DKAalborg University · DK

Funding

aase og ejnar danielsens fond 10-000912aase og ejnar danielsens fond 2013det obelske familiefond 2015det obelske familiefond 20461karla og verner soerensens almennyttige forskningsfond 2014karla og verner soerensens almennyttige forskningsfond 2018karla og verner soerensens almennyttige forskningsfond 701783spar nord fonden 2013
6 · The paper itself

Abstract

objectiveMagnetic resonance imaging (MRI)-based techniques for non-invasive assessing liver iron concentration (LIC) in patients with iron overload have a limited upper measuring range around 35 mg/g dry weight, caused by signal loss from accelerated T1-, T2-, T2* shortening with increasing LIC. Expansion of this range is necessary to allow evaluation of patients with very high LIC.

aimTo assess measuring range of a gradient-echo R2* method and a T1-weighted spin-echo (SE), signal intensity ratio (SIR)-based method (TE = 25 ms, TR = 560 ms), and to extend the upper measuring range of the SIR method by optimizing echo time (TE) and repetition time (TR) in iron-loaded minipigs.

methodsThirteen mini pigs were followed up during dextran-iron loading with repeated percutaneous liver biopsies for chemical LIC measurement and MRIs for parallel non-invasive estimation of LIC (81 examinations) using different TEs and TRs.

resultsSIR and R2* method had similar upper measuring range around 34 mg/g and similar method agreement. Using TE = 12 ms and TR = 1200 ms extended the upper measuring range to 115 mg/g and yielded good method of agreement. DISCUSSION: The wider measuring range is likely caused by lesser sensitivity of the SE sequence to iron, due to shorter TE, leading to later signal loss at high LIC, allowing evaluation of most severe hepatic iron overload. Validation in iron-loaded patients is necessary.

Indexed as

DextransIron OverloadAnimalsBiopsyCalibrationIronLiverMagnetic Resonance ImagingSwineSwine, MiniatureDextransIronExperimental animal modelsIron overloadLiver iron concentrationMagnetic resonance imagingQuantitative imaging

Identifiers

PMID35038062
PMCPMC9463247
OpenAlexW4205253316

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.