Evidence map›Paper›PMID 35037075›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2022

Biomechanical comparison of acetabular fracture fixation with stand-alone THA or in combination with plating.

Lisa Wenzel, Sabrina Sandriesser, Claudio Glowalla, Boyko Gueorguiev, Mario Perl, Fabian M Stuby, Peter Augat, Sven Hungerer

Open access · hybridAbstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 3 countries.

Lisa Wenzel *Department of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Sabrina Sandriesser *Institute for Biomechanics, Berufsgenossenschaftliche Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany. Sabrina.Sandriesser@bgu-murnau.de.ORCID http://orcid.org/0000-0002-9439-0016
Claudio GlowallaDepartment of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Boyko GueorguievAO Research Institute Davos, Clavadelerstr. 8, 7270, Davos, Switzerland.
Mario PerlDepartment of Trauma and Orthopedic Surgery, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg, Maximiliansplatz. 2, 91012, Erlangen, Germany.
Fabian M StubyDepartment of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Peter AugatInstitute for Biomechanics, Berufsgenossenschaftliche Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Sven HungererDepartment of Trauma and Orthopedic Surgery, Berufsgenossenschaftliche Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418, Murnau, Germany.
Paracelsus Medical University · ATAO Foundation · CHBerufsgenossenschaftliche Unfallklinik Murnau · DEFriedrich-Alexander-Universität Erlangen-Nürnberg · DE

Funding

Paracelsus Medizinische Privatuniversität R-18/05/113-WEN
6 · The paper itself

Abstract

purposeA common surgical treatment in anterior column acetabular fractures with preexisting osteoarthritis is THA, which is commonly combined with plate osteosynthesis. Implantation of a solitary revision cup cranially fixed to the os ilium is less common. The purpose of this study was to compare the stabilization of anterior column acetabular fractures fixed with a cranial socket revision cup with flange and iliac peg or with a suprapectineal plate osteosynthesis combined with an additional revision cup.

methodsIn 20 human hemipelves, an anterior column fracture was stabilized by either a cranial socket revision cup with integrated flange (CF = Cup with Flange) or by a suprapectineal plate combined with a revision cup (CP = Cup and Plate). Each specimen was loaded under a stepwise increasing dynamic load protocol. Initial construct stiffness, interfragmentary movements along the fracture line, as well as femoral head movement in relation to the acetabulum were analyzed.

resultsBoth groups showed comparable initial construct stiffness (CP: 3180 ± 1162 N/mm and CF: 3754 ± 668 N/mm; p = 0.158). At an applied load of 1400 N, interfragmentary movements at the acetabular (p = 0.139) and the supraacetabular region (p = 0.051) revealed comparable displacement for both groups and remained below 1 mm. Femoral head movement in relation to the acetabulum also remained below 1 mm for both test groups (p = 0.260).

conclusionFrom a biomechanical point of view, both surgical approaches showed comparable fracture reduction in terms of initial construct stiffness and interfragmentary movement. The potential benefit of the less-invasive cranial socket revision cup has to be further investigated in clinical studies.

Indexed as

Arthroplasty, Replacement, HipFractures, BoneHip FracturesSpinal FracturesAcetabulumBiomechanical PhenomenaFracture Fixation, InternalHumansAcetabular fractureAcute total hip arthroplastyAnterior columnBiomechanicsRevision cupSuprapectineal plate

Identifiers

PMID35037075
PMCPMC9360095
OpenAlexW4206385570

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.