Evidence map›Paper›PMID 35036896›Full record

ReviewMaterials today. Bio2022

Aurora Borealis in dentistry: The applications of cold plasma in biomedicine.

S Lata, Shibani Chakravorty, Tamoghni Mitra, Prasanti Kumari Pradhan, Soumyakanta Mohanty, Paritosh Patel, Ealisha Jha, Pritam Kumar Panda, Suresh K Verma, Mrutyunjay Suar

Open access · goldAbstract readReview
In one paragraph

Review in Materials today. Bio, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed, 1 pooled it
7.9field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 1 synthesis or guideline pooled it, 77 citations in OpenAlex.

  1. Pooled it
  2. E‑Cigarettes Generate Gas Phase Ions.Environment & health (Washington, D.C.) · 2026
    Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Anti-Inflammatory Activity of No-Ozone Cold Plasma inInternational journal of molecular sciences · 2024
    Article
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

S LataKalinga Institute of Dental Sciences, Department of Conservative Dentistry and Endodontics, KIIT University, Bhubaneswar, 751024, India.
Shibani ChakravortyKalinga Institute of Dental Sciences, Department of Conservative Dentistry and Endodontics, KIIT University, Bhubaneswar, 751024, India.
Tamoghni MitraSchool of Biotechnology, KIIT University, Bhubaneswar, 751024, India.
Prasanti Kumari PradhanKalinga Institute of Dental Sciences, Department of Conservative Dentistry and Endodontics, KIIT University, Bhubaneswar, 751024, India.
Soumyakanta MohantyDepartment of Conservative Dentistry and Endodontics, SCB Dental College and Hospital, Cuttack, 753007, India.
Paritosh PatelSchool of Biotechnology, KIIT University, Bhubaneswar, 751024, India.
Ealisha JhaSchool of Biotechnology, KIIT University, Bhubaneswar, 751024, India.
Pritam Kumar PandaCondensed Matter Theory Group, Materials Theory Division, Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20, Uppsala, Sweden.
Suresh K VermaSchool of Biotechnology, KIIT University, Bhubaneswar, 751024, India.
Mrutyunjay SuarSchool of Biotechnology, KIIT University, Bhubaneswar, 751024, India.
KIIT University · INUppsala University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Plasma is regularly alluded to as the fourth form of matter. Its bounty presence in nature along with its potential antibacterial properties has made it a widely utilized disinfectant in clinical sciences. Thermal plasma and non-thermal (or cold atmospheric) plasma (NTP) are two types of plasma. Atoms and heavy particles are both available at the same temperature in thermal plasma. Cold atmospheric plasma (CAP) is intended to be non-thermal since its electrons are hotter than the heavier particles at ambient temperature. Direct barrier discharge (DBD), atmospheric plasma pressure jet (APPJ), etc. methods can be used to produce plasma, however, all follow a basic concept in their generation. This review focuses on the anticipated uses of cold atmospheric plasma in dentistry, such as its effectiveness in sterilizing dental instruments by eradicating bacteria, its advantage in dental cavity decontamination over conventional methods, root canal disinfection, its effects on tooth whitening, the benefits of plasma treatment on the success of dental implant placement, and so forth. Moreover, the limitations and probable solutions has also been anticipated. These conceivable outcomes thus have proclaimed the improvement of more up-to-date gadgets, for example, the plasma needle and plasma pen, which are efficient in treating the small areas like root canal bleaching, biofilm disruption, requiring treatment in dentistry.

Indexed as

Cold atmospheric plasmaDental implant modificationDentistryNon-thermal plasmaPlasma penSterilizationTooth disinfection

Identifiers

PMID35036896
PMCPMC8743205
OpenAlexW4200212020

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.