ReviewLa Radiologia medica2022
JET 7 catheter for direct aspiration in carotid T occlusions: preliminary experience and literature review.
Review in La Radiologia medica, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 7 citations in OpenAlex.
- Combined Aspiration and Stent Retriever Thrombectomy for Distal Carotid Artery Occlusion Using Balloon Guide versus Non-Balloon Guide Catheter.Journal of clinical medicine · 2024Article
- First-line thrombectomy strategy for carotid terminus occlusions: A systematic review and meta-analysis.World neurosurgery: X · 2023Review
- Technical note and first results on JET 7 thromboaspiration device for T-ICA occlusions.BMC neurology · 2022Article
- Comparison of First-Pass Effect in Aspiration vs. Stent-Retriever for Acute Intracranial ICA Occlusion.Frontiers in neurology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveWe report our preliminary experience with the Penumbra JET 7 reperfusion catheter (JET 7), a new large-bore (0.072″) aspiration catheter, in patients with acute ischemic stroke (AIS) due to carotid T occlusion.
methodsData of all eligible patients who received A Direct Aspiration First Pass Technique (ADAPT) for AIS due to carotid T occlusion at our center from March 2018 through June 2020 were retrospectively reviewed. The safety and performance of JET 7 cases and smaller large-bore catheters (LBCs) were compared.
resultsJET 7 was used in 19 patients, and smaller LBCs were used in 41 patients. Median puncture to revascularization time was significantly different between the JET 7 and the smaller LBCs (16 vs. 27 min; P = 0.011). The rate of patients who received rescue therapy with a stent retriever was also significantly different between the JET 7 cases and the smaller LBCs cases (5.3% vs. 22.0%; P = 0.046). Successful revascularization (TICI ≥ 2b) was achieved in 94.7% of JET 7 cases and 75.6% of smaller LBCs cases (P = 0.148). Good functional outcome (mRS 0-2) at 90 days occurred in 63.2% of JET 7 cases and 46.3% of smaller LBCs cases (P = 0.274).
conclusionsIn this early experience, ADAPT with JET 7 could be considered as one of the possible first-line therapies in carotid T occlusion, showing good rate of vascularization and lower rate of rescue therapy in comparison with smaller LBCs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.