Evidence map›Paper›PMID 35032314›Full record

ArticleEndocrine2022

Diagnostic efficacy, performance and safety of side-cut core needle biopsy for thyroid nodules: comparison of automated and semi-automated biopsy needles.

Ji Yeon Park, Seong Yoon Yi, Soo Heui Baek, Yu Hyun Lee, Heon-Ju Kwon, Hee Jin Park

Abstract read
PubMed Publisher
In one paragraph

Article in Endocrine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ji Yeon ParkDepartment of Radiology, Inje University Ilsan Paik Hospital, Goyang, Republic of Korea.ORCID 0000-0002-4933-0292
Seong Yoon YiDivision of Hematology-Oncology, Department of Internal Medicine, Inje University Ilsan Paik Hospital, Goyang, Republic of Korea. Dr-Yi@paik.ac.kr.ORCID 0000-0002-5468-3674
Soo Heui BaekDepartment of Radiology, Daerim St. Mary's Hospital, Seoul, Republic of Korea.ORCID 0000-0001-7030-8156
Yu Hyun LeeDepartment of Radiology, Myongji Hospital, Hanyang University College of Medicine, Goyang, Republic of Korea.ORCID 0000-0002-7635-6762
Heon-Ju KwonDepartment of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-8157-6575
Hee Jin ParkDepartment of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-3135-0586

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study was performed to compare the utility of the semi-automated and automated side-cut core biopsy needles for thyroid nodules.

methodsBetween January 2014 and March 2020, biopsy was performed for 278 thyroid nodules using the semi-automated core needle and for 225 nodules using the automated core needle. Nondiagnostic rate, inconclusive rate, diagnostic performance and complication rates were evaluated and compared between two core needle types.

resultsThere were 1.2% (6/503) nondiagnostic results and 15.9% (80/503) inconclusive results. Nondiagnostic rate between two needle types was not significantly different. The semi-automated type (33/278, 11.9%) showed lower inconclusive rate than the automated type (47/225, 20.9%) (p = 0.006). The sensitivity, specificity, PPV, NPV and diagnostic accuracy for diagnosis of malignancy of the semi-automated type were 70.18, 100, 100, 84.96 and 88.89%, respectively; the corresponding rates of automated type were 70.45, 100, 100, 86.6, and 89.84%. There were 12 minor complications: four hematomas (4/278, 1.4%) for the semi-automated type and eight hematomas (8/225, 3.6%) for the automated type, which difference was not statistically significant.

conclusionCore needle biopsy for thyroid nodules using either the semi-automated or automated needle is a safe diagnostic tool. Semi-automated needle has lower inconclusive rate than automated needle.

Indexed as

Thyroid NeoplasmsThyroid NoduleBiopsy, Fine-NeedleBiopsy, Large-Core NeedleHematomaHumansNeedlesRetrospective StudiesBiopsyDiagnosisThyroid noduleUltrasonography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.