The influence of delivery power losses and full operating parametry on the effectiveness of diode visible-near infra-red (445-1064 nm) laser therapy in dentistry-a multi-centre investigation.
Article in Lasers in medical science, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- A Dosimetric Reappraisal of the Photobiomodulation Literature Assessing Animal Safety and Phototoxicity Evidence for Photobiomodulation in Oncology: Phantom Dangers.Biomedicines · 2026Review
- Effectiveness of Diode Laser Treatment in Managing Dentin Hypersensitivity in Vietnamese Adults: A Six-Month Prospective Study.Clinical, cosmetic and investigational dentistry · 2026Article
- Synergistic antibiofilm activity of methylene blue and silver nanoparticle-mediated photothermal therapy against Enterococcus faecalis biofilm.Scientific reports · 2025Article
- Assessment of the influence of 660 and 808-nm PBM treatments on mitochondrial oxygen consumption of MG-63 osteoblast: a 3D cell culture study.Lasers in medical science · 2025Article
- Photothermal Effects of High-Energy Photobiomodulation Therapies: An In Vitro Investigation.Biomedicines · 2023Article
- Comparison of the Penetration Depth of 905 nm and 1064 nm Laser Light in Surface Layers of Biological Tissue Ex Vivo.Biomedicines · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The development of protocols for laser-assisted therapy demands strict compliance with comprehensive operating parametry. The purpose of this investigation was to examine the accuracy of correlation between laser control panel and fibre emission power values in a selection of diode dental lasers. Through retrospective analysis using successive systematic review and meta-analysis, it is clear that there is inconsistency in the details, and possible inaccuracies in laser power applied and associated computed data. Through a multi-centre investigation, 38 semi-conductor ("diode") dental laser units were chosen, with emission wavelengths ranging from 445 to 1064 nm. Each unit had been recently serviced according to manufacturer's recommendations, and delivery fibre assembly checked for patency and correct alignment with the parent laser unit. Subject to the output capacity of each laser, four average power values were chosen using the laser control panel-100 mW, 500 mW, 1.0 W, and 2.0 W. Using a calibrated power meter, the post-fibre emission power value was measured, and a percentage power loss calculated. For each emission, a series of six measurements were made and analysed to investigate sources of power losses along the delivery fibre, and to evaluate the precision of power loss determinations. Statistical analysis of a dataset comprising % deviations from power setting levels was performed using a factorial ANOVA model, and this demonstrated very highly significant differences between devices tested and emission power levels applied (p < 10-142 and < 10-52 respectively). The devices × emission power interaction effect was also markedly significant (p < 10-66), and this confirmed that differences observed in these deviations for each prior power setting parameter were dependent on the device employed for delivery. Power losses were found to be negatively related to power settings applied. Significant differences have emerged to recommend the need to standardize a minimum set of parameters that should form the basis of comparative research into laser-tissue interactions, both in vitro and in vivo.