ArticleJournal of biomolecular techniques : JBT2021
Rapid, Affordable, and Scalable SARS-CoV-2 Detection From Saliva.
Article in Journal of biomolecular techniques : JBT, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Here we present an inexpensive, rapid, and robust reverse-transcription loop-mediated isothermal amplification (RT-LAMP)-based severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection method that is easily scalable, enabling point-of-care facilities and clinical labs to determine results from patients' saliva directly in 30 minutes for less than $2 per reaction. The method uses a novel combination of widely available reagents that can be prepared in bulk, plated, and frozen and remain stable until samples are received. This innovation dramatically reduces preparation time, enabling high-throughput automation and testing with time to results (including setup) in less than 1 hour for 96 patient samples simultaneously when using a 384-well format. By using a dual reporter (phenol red pH indicator for end-point detection and SYTO-9 fluorescent dye for real time), the assay also provides internal validation of results and redundancy in the event of an instrument malfunction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.