ArticleEuropean journal of medical research2022
Breakage of intramedullary femoral nailing or femoral plating: how to prevent implant failure.
Article in European journal of medical research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 18 citations in OpenAlex.
- Repurposing Metformin to Promote Fracture Callus Maturation via AMPK-Driven Metabolic Activation.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026Article
- Callus formation during healing is guided by local strain: a retrospective clinical observation.BMC musculoskeletal disorders · 2026Observational
- Article
- Article
- The Recent Developments of Thermomechanical Processing for Biomedical Mg Alloys and Their Clinical Applications.Materials (Basel, Switzerland) · 2025Review
- Subcapital Femoral Fracture with Cephalomedullary Nail Lag Screw Failure after Healed Intertrochanteric Fracture: A Case Report.Orthopedic reviews · 2025Article
- Comparative Study of Exchange Nailing and Augmentative Plating for Treating Aseptic Nonunion of Femoral Shafts Post Intramedullary Nailing: A Single-Blind, Multicentric Randomized Clinical Trial.Journal of clinical medicine · 2024Article
- Review
- Does the Instability of Pertrochanteric Fractures in the Elderly Correlate With Weakened Gluteal Muscles?Cureus · 2024Article
- Biomechanical evaluation of Gamma 3 nail with anti-rotation screw fixation for unstable femoral neck fractures: a biomechanical study.Scientific reports · 2024Article
- Surgical fixation of ipsilateral femoral neck and shaft fractures: a matter of debate?EFORT open reviews · 2023Review
- Management of Traumatic Femur Fractures: A Focus on the Time to Intramedullary Nailing and Clinical Outcomes.Diagnostics (Basel, Switzerland) · 2023Article
- Use of minimally invasive cerclage wiring for displaced major fragments of femoral shaft fractures after intramedullary nailing promotes bone union and a functional outcome.Journal of orthopaedic surgery and research · 2022Article
- Clinical Outcomes of Treatment Strategies for Postoperative Plate Fracture and In Situ Fracture of the Femoral Shaft.BioMed research international · 2022Article
- Prediction of the intramedullary nail size by fibula length in bilateral femur fractures.Colombia medica (Cali, Colombia)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionIntramedullary (IM) fixation is the dominant treatment for pertrochanteric and femoral shaft fractures. In comparison to plate osteosynthesis (PO), IM fixation offers greater biomechanical stability and reduced non-union rates. Due to the minimally invasive nature, IM fixations are less prone to approach-associated complications, such as soft-tissue damage, bleeding or postoperative infection, but they are more prone to fat embolism. A rare but serious complication, however, is implant failure. Thus, the aim of this study was to identify possible risk factors for intramedullary fixation (IMF) and plate osteosynthesis (PO) failure. MATERIALS AND
methodsWe searched our trauma surgery database for implant failure, intramedullary and plate osteosynthesis, after proximal-pertrochanteric, subtrochanteric-or femoral shaft fractures between 2011 and 2019. Implant failures in both the IMF and PO groups were included. Demographic data, fracture type, quality of reduction, duration between initial implantation and nail or plate failure, the use of cerclages, intraoperative microbiological samples, sonication, and, if available, histology were collected.
resultsA total of 24 femoral implant failures were identified: 11 IMFs and 13 POs. The average age of patients in the IM group was 68.2 ± 13.5 years and in the PO group was 65.6 ± 15.0 years, with men being affected in 63.6% and 39.5% of cases, respectively. A proximal femoral nail (PFN) anti-rotation was used in 7 patients, a PFN in one and a gamma nail in two patients. A total of 6 patients required cerclage wires for additional stability. A combined plate and intramedullary fixation was chosen in one patient. Initially, all intramedullary nails were statically locked. Failures were observed 34.1 weeks after the initial surgery on average. Risk factors for implant failure included the application of cerclage wires at the level of the fracture (n = 5, 21%), infection (n = 2, 8%), and the use of an additional sliding screw alongside the femoral neck screw (n = 3, 13%). In all patients, non-union was diagnosed radiographically and clinically after 6 months (n = 24, 100%). In the event of PO failure, the placement of screws within all screw holes, and interprosthetic fixation were recognised as the major causes of failure.
conclusionIntramedullary or plate osteosynthesis remain safe and reliable procedures in the treatment of proximal femoral fractures (pertrochanteric, subtrochanteric and femoral shaft fractures). Nevertheless, the surgeon needs to be aware of several implant-related limitations causing implant breakage. These may include the application of tension band wiring which can lead to a too rigid fixation, or placement of cerclage wires at the fracture site.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.