Evidence map›Paper›PMID 35025945›Full record

ArticlePloS one2022

Detection of COVID-19 in smartphone-based breathing recordings: A pre-screening deep learning tool.

Mohanad Alkhodari, Ahsan H Khandoker

Abstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Article
  5. Article
  6. Review
  7. Article
  8. Omicron detection with large language models and YouTube audio data.medRxiv : the preprint server for health sciences · 2024
    Article
  9. Article
  10. A Development of a Sound Recognition-Based Cardiopulmonary Resuscitation Training System.IEEE journal of translational engineering in health and medicine · 2024
    Article
  11. Article
  12. TO-LAB model: Real time Touchless Lung Abnormality detection model using USRP based machine learning algorithm.Technology and health care : official journal of the European Society for Engineering and Medicine · 2024
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Mohanad AlkhodariHealthcare Engineering Innovation Center (HEIC), Department of Biomedical Engineering, Khalifa University, Abu Dhabi, UAE.ORCID 0000-0002-5248-6327
Ahsan H KhandokerHealthcare Engineering Innovation Center (HEIC), Department of Biomedical Engineering, Khalifa University, Abu Dhabi, UAE.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study was sought to investigate the feasibility of using smartphone-based breathing sounds within a deep learning framework to discriminate between COVID-19, including asymptomatic, and healthy subjects. A total of 480 breathing sounds (240 shallow and 240 deep) were obtained from a publicly available database named Coswara. These sounds were recorded by 120 COVID-19 and 120 healthy subjects via a smartphone microphone through a website application. A deep learning framework was proposed herein that relies on hand-crafted features extracted from the original recordings and from the mel-frequency cepstral coefficients (MFCC) as well as deep-activated features learned by a combination of convolutional neural network and bi-directional long short-term memory units (CNN-BiLSTM). The statistical analysis of patient profiles has shown a significant difference (p-value: 0.041) for ischemic heart disease between COVID-19 and healthy subjects. The Analysis of the normal distribution of the combined MFCC values showed that COVID-19 subjects tended to have a distribution that is skewed more towards the right side of the zero mean (shallow: 0.59±1.74, deep: 0.65±4.35, p-value: <0.001). In addition, the proposed deep learning approach had an overall discrimination accuracy of 94.58% and 92.08% using shallow and deep recordings, respectively. Furthermore, it detected COVID-19 subjects successfully with a maximum sensitivity of 94.21%, specificity of 94.96%, and area under the receiver operating characteristic (AUROC) curves of 0.90. Among the 120 COVID-19 participants, asymptomatic subjects (18 subjects) were successfully detected with 100.00% accuracy using shallow recordings and 88.89% using deep recordings. This study paves the way towards utilizing smartphone-based breathing sounds for the purpose of COVID-19 detection. The observations found in this study were promising to suggest deep learning and smartphone-based breathing sounds as an effective pre-screening tool for COVID-19 alongside the current reverse-transcription polymerase chain reaction (RT-PCR) assay. It can be considered as an early, rapid, easily distributed, time-efficient, and almost no-cost diagnosis technique complying with social distancing restrictions during COVID-19 pandemic.

Indexed as

AdolescentAdultAgedCOVID-19Deep LearningFemaleHumansMaleMass ScreeningMiddle AgedNeural Networks, ComputerPandemicsRespiratory SoundsROC CurveSARS-CoV-2Smartphone

Identifiers

PMID35025945
PMCPMC8758005

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.