Evidence map›Paper›PMID 35023725›Full record

ArticleAnalytical chemistry2022

Sensitive, Single-Pot, Two-Stage Assay for Hepatitis Viruses.

Youngung Seok, Qingtian Yin, Huiwen Bai, Haim H Bau

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.3field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Youngung SeokDepartment of Mechanical Engineering and Applied Mechanics, University of Pennsylvania (UPenn), 216 Towne Building, 220 South 33rd Street, Philadelphia, Pennsylvania 19104, United States.ORCID 0000-0002-2021-8424
Qingtian YinDepartment of Mechanical Engineering and Applied Mechanics, University of Pennsylvania (UPenn), 216 Towne Building, 220 South 33rd Street, Philadelphia, Pennsylvania 19104, United States.
Huiwen BaiDepartment of Mechanical Engineering and Applied Mechanics, University of Pennsylvania (UPenn), 216 Towne Building, 220 South 33rd Street, Philadelphia, Pennsylvania 19104, United States.
Haim H BauDepartment of Mechanical Engineering and Applied Mechanics, University of Pennsylvania (UPenn), 216 Towne Building, 220 South 33rd Street, Philadelphia, Pennsylvania 19104, United States.
University of Pennsylvania · US

Funding

Minimally-instrumented home HIV detection and care linkage systemR33HD101937 · NICHD · UNIVERSITY OF PENNSYLVANIA · PI BAU, HAIM H · 2023 to 2025
$1.4M
Minimally-instrumented home HIV detection and care linkage systemR61HD101937 · NICHD · UNIVERSITY OF PENNSYLVANIA · PI BAU, HAIM H · 2019 to 2021
$1.4M
NICHD NIH HHS R33 HD101937NICHD NIH HHS R61 HD101937
6 · The paper itself

Abstract

When left untreated, hepatitis B virus (HBV) and hepatitis C virus (HCV) infections may cause severe illnesses. Since these infections remain asymptomatic for many years, routine screening of populations at risk is critical for therapy initiation. The current standard of care mandates a screening antibody test for HCV, followed by a confirmatory laboratory-based molecular test and treatment. Multiple visits to the clinic are inconvenient, and many patients fail to follow up. To address this challenge, we have developed sensitive, two-stage, isothermal molecular (Penn-RAMP) point-of-care tests to enable test and treat strategy. Penn-RAMP's first stage is comprised of recombinase polymerase amplification (RPA), while its second stage is comprised of loop-mediated isothermal amplification (LAMP). Penn-RAMP is more sensitive than LAMP or RPA alone. We designed a custom pre-LAMP buffer to maximize the volume of RPA products that can be added to the LAMP reaction mix without inhibition and forward and backward primers. Penn-RAMP was implemented in a single pot comprised of two compartments separated by a thermally removable barrier. RAMP's first stage is carried out above the barrier at the RPA incubation temperature. When the pot is heated to the LAMP incubation temperature, the barrier melts away, and the RPA reaction volume mixes with the pre-LAMP buffer, facilitating second-stage amplification. This entire process can be carried out with minimal instrumentation. Our HBV and HCV tests detect, respectively, as few as 10 and 25 virions within 30 min. The viral load can be estimated based on signal threshold time.

Indexed as

Hepatitis B virusNucleic Acid Amplification TechniquesDNA PrimersHumansRecombinasesSensitivity and SpecificityViral LoadDNA PrimersRecombinases

Identifiers

PMID35023725
PMCPMC11129555
OpenAlexW4205589038

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.