ArticleJournal of applied clinical medical physics2022

Reproducibility of deep inspiration breath-hold technique for left-side breast cancer with respiratory monitoring device, Abches.

Masahide Saito, Daichi Kajihara, Hidekazu Suzuki, Takafumi Komiyama, Kan Marino, Shinichi Aoki, Koji Ueda, Naoki Sano, Hiroshi Onishi

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Masahide SaitoDepartment of Radiology, University of Yamanashi, Chuo City, Yamanashi, Japan.
Daichi KajiharaDepartment of Radiology, University of Yamanashi, Chuo City, Yamanashi, Japan.
Hidekazu SuzukiDepartment of Radiology, University of Yamanashi, Chuo City, Yamanashi, Japan.
Takafumi KomiyamaDepartment of Radiology, University of Yamanashi, Chuo City, Yamanashi, Japan.
Kan MarinoDepartment of Radiology, University of Yamanashi, Chuo City, Yamanashi, Japan.
Shinichi AokiDepartment of Radiology, University of Yamanashi, Chuo City, Yamanashi, Japan.
Koji UedaDepartment of Radiology, University of Yamanashi, Chuo City, Yamanashi, Japan.
Naoki SanoDepartment of Radiology, University of Yamanashi, Chuo City, Yamanashi, Japan.
Hiroshi OnishiDepartment of Radiology, University of Yamanashi, Chuo City, Yamanashi, Japan.
University of Yamanashi · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to evaluate the reproducibility of deep inspiration breath-hold (DIBH) using a respiratory control device, Abches, in patients with left-sided breast cancer. MATERIAL AND

methodsAbches comprises a main body, an indicator panel, and two fulcrums, one each on the chest and abdomen. Forty left side breast cancer patients treated with DIBH using abches were enrolled in this study. For all patients, CT images were taken three times to confirm the target position inside the body and to check the breath-hold reproducibility. Three anatomical points on the nipple, sternum, and heart were selected as measurement points on CT images. After measuring the coordinates, breath-hold reproducibility was defined as the mean of the absolute difference in the coordinates between the three CT images. The maximum differences were also investigated. In addition, the dice similarity coefficient (DSC) was calculated to examine the displacement of the heart volume in detail. Moreover, digitally reconstructed radiographs (DRRs) and linac graphs (LGs) were used to measure the positional accuracy of the chest and heart.

resultsThe reproducibility in all patients was within 0.75 mm for the nipple, 0.78 mm for the sternum, and 2.18 mm for the heart in each direction. Similarly, the maximum displacements for all patients were within 1.90 mm, 1.69 mm, and 4.75 mm, respectively, in each direction. For heart volume, the average DSC for all cases was 0.93 ± 0.01. The differences between the DRR and LG images were 1.70 ± 1.10 mm and 2.10 ± 1.60 mm, for the chest and heart, respectively.

conclusionOur study showed that DIBH using Abches can be performed with good target reproducibility of less than 3 mm with proper breath-hold practice, whereas the heartbeat-derived reproducibility of the cardiac position is poor and needs to be monitored carefully during treatment simulation.

Indexed as

Breast NeoplasmsThoracic WallUnilateral Breast NeoplasmsBreath HoldingFemaleHeartHumansOrgans at RiskRadiotherapy DosageRadiotherapy Planning, Computer-AssistedReproducibility of ResultsDIBHleft-side breast cancerradiotherapyreproducibility

Identifiers

PMID35018712
PMCPMC8992950
OpenAlexW4205819393

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.