Evidence map›Paper›PMID 35014729›Full record

ArticleMagnetic resonance in medicine2022

Volumetric and multispectral DWI near metallic implants using a non-linear phase Carr-Purcell-Meiboom-Gill diffusion preparation.

Philip K Lee, Daehyun Yoon, Jesse K Sandberg, Shreyas S Vasanawala, Brian A Hargreaves

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Philip K LeeRadiology, Stanford University, Stanford, California, USA.ORCID 0000-0002-7945-902X
Daehyun YoonRadiology, Stanford University, Stanford, California, USA.ORCID 0000-0001-9367-9152
Jesse K SandbergRadiology, Stanford University, Stanford, California, USA.
Shreyas S VasanawalaRadiology, Stanford University, Stanford, California, USA.
Brian A HargreavesRadiology, Stanford University, Stanford, California, USA.

Funding

Training and DisseminationP41EB015891 · NIBIB · STANFORD UNIVERSITY · PI GLOVER, GARY H · 2012 to 2019
$10.7M
High-Resolution Whole-Breast MRI at 3.0TR01EB009055 · NIBIB · STANFORD UNIVERSITY · PI BRUCE L DANIEL, Brian Andrew Hargreaves · 2008 to 2026
$7.5M
Novel PET/MR Imaging Approach for Persistent Postsurgical Pain Following Joint ReplacementR01AR077706 · NIAMS · UNIVERSITY OF WISCONSIN-MADISON · PI SANDIP BISWAL · 2021 to 2026
$2.6M
Quantitative 3D Diffusion and Relaxometry MRI of the KneeR01AR063643 · NIAMS · STANFORD UNIVERSITY · PI HARGREAVES, BRIAN ANDREW · 2013 to 2017
$2.5M
MRI near Total Joint replacementsR01EB017739 · NIBIB · STANFORD UNIVERSITY · PI HARGREAVES, BRIAN ANDREW · 2014 to 2018
$2.4M
NIAMS NIH HHS R01 AR063643NIAMS NIH HHS R01 AR077706NIBIB NIH HHS P41 EB015891NIBIB NIH HHS R01 EB009055NIBIB NIH HHS R01 EB017739
6 · The paper itself

Abstract

purposeDWI near metal implants has not been widely explored due to substantial challenges associated with through-slice and in-plane distortions, the increased encoding requirement of different spectral bins, and limited SNR. There is no widely adopted clinical protocol for DWI near metal since the commonly used EPI trajectory fails completely due to distortion from extreme off-resonance ranging from 2 to 20 kHz. We present a sequence that achieves DWI near metal with moderate b-values (400-500 s/mm THEORY AND

methodsMultispectral excitation with Cartesian sampling, view angle tilting, and kz phase encoding reduce in-plane and through-plane off-resonance artifacts, and Carr-Purcell-Meiboom-Gill (CPMG) spin-echo refocusing trains counteract T2* effects. The effect of random phase on the refocusing train is eliminated using a stimulated echo diffusion preparation. Root-flipped Shinnar-Le Roux refocusing pulses permits preparation of a high spectral bandwidth, which improves imaging times by reducing the number of excitations required to cover the desired spectral range. B

resultsNon-linear phase refocusing pulses reduces the peak B

conclusionVolumetric and multispectral DW imaging near metal can be achieved with a 3D encoded sequence.

Indexed as

ArtifactsGillsAnimalsDiffusion Magnetic Resonance ImagingPhantoms, ImagingProstheses and Implantsdiffusion preparationdiffusion weighted imagingdistortionless diffusionmultispectral imagingroot-flipped SLR pulses

Identifiers

PMID35014729
PMCPMC8979554

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.