Evidence map›Paper›PMID 35013488›Full record

ArticleScientific reports2022

Reliability of hip joint position sense tests using a clinically applicable measurement tool in elderly participants with unilateral hip osteoarthritis.

Ravi Shankar Reddy, Jaya Shanker Tedla, Mastour Saeed Alshahrani, Faisal Asiri, Venkata Nagaraj Kakaraparthi, Paul Silvian Samuel, Praveen Kumar Kandakurti

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
4.4field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Observational
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Ravi Shankar ReddyDepartment of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia. rshankar@kku.edu.sa.ORCID 0000-0001-6638-0585
Jaya Shanker TedlaDepartment of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0002-2876-4227
Mastour Saeed AlshahraniDepartment of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0003-2714-7785
Faisal AsiriDepartment of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0003-2015-4974
Venkata Nagaraj KakaraparthiDepartment of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0002-8145-1625
Paul Silvian SamuelDepartment of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.ORCID 0000-0002-4920-6347
Praveen Kumar KandakurtiCollege of Health Sciences, Gulf Medical University, Ajman, United Arab Emirates.ORCID 0000-0003-2669-4488
King Khalid University · SAGulf Medical University · AE

Funding

King Khalid University RGP. 2/40/42
6 · The paper itself

Abstract

Hip joint proprioception is vital in maintaining posture and stability in elderly individuals. Examining hip joint position sense (JPS) using reliable tools is important in contemporary clinical practice. The objective of this study is to evaluate the intra-rater and inter-rater reliability of hip JPS tests using a clinically applicable measurement tool in elderly individuals with unilateral hip osteoarthritis (OA). Sixty-two individuals (mean age = 67.5 years) diagnosed with unilateral hip OA participated in this study. The JPS tests were evaluated using a digital inclinometer in hip flexion and abduction directions. The absolute difference between target and reproduced angle (repositioning error) in degrees was taken to measure JPS accuracy. The intraclass correlation coefficient (ICC (2.k), was used to assess the reliability. The Intra rater-reliability for hip JPS tests showed very good agreement in the lying position (hip flexion-ICC = 0.88-0.92; standard error of measurement (SEM) = 0.06-0.07, hip abduction-ICC = 0.89-0.91; SEM = 0.06-0.07) and good agreement in the standing position (hip flexion-ICC = 0.69-0.72; SEM = 0.07, hip abduction-ICC = 0.66-0.69; SEM = 0.06-0.08). Likewise, inter-rater reliability for hip JPS tests demonstrated very good agreement in the lying position (hip flexion-ICC = 0.87-0.89; SEM = 0.06-0.07, hip abduction-ICC = 0.87-0.91; SEM = 0.07) and good agreement in the standing position (hip flexion-ICC = 0.64-0.66; SEM = 0.08, hip abduction-ICC = 0.60-0.72; SEM = 0.06-0.09). The results support the use of hip JPS tests in clinical practice and should be incorporated in assessing and managing elderly participants with hip OA.

Indexed as

ProprioceptionAgedAge FactorsBiomechanical PhenomenaFemaleHip JointHumansMaleMiddle AgedObserver VariationOsteoarthritis, HipPhysical ExaminationPredictive Value of TestsRange of Motion, ArticularReproducibility of Results

Identifiers

PMID35013488
PMCPMC8748869
OpenAlexW4206247990

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.