Evidence map›Paper›PMID 35009773›Full record

ArticleSensors (Basel, Switzerland)2021

Wearable E-Textile and CNT Sensor Wireless Measurement System for Real-Time Penile Erection Monitoring.

Yongki Heo, Jinhyung Kim, Cheolung Cha, Kyusik Shin, Jihyoung Roh, Jungki Jo

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. Wearable penile devices: the TechRing.Translational andrology and urology · 2025
    Article
  3. Review
  4. Penile Erection Morphometry: The Need for a Novel Approach.The world journal of men's health · 2024
    Review
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Yongki HeoDepartment of Medical and Digital Engineering, Hanyang University, Seoul 04763, Korea.ORCID 0000-0001-9945-3613
Jinhyung KimSmart Sensor Research Center, Korea Electronics Technology Institute, Seongnam 13509, Korea.
Cheolung ChaSmart Sensor Research Center, Korea Electronics Technology Institute, Seongnam 13509, Korea.
Kyusik ShinSmart Sensor Research Center, Korea Electronics Technology Institute, Seongnam 13509, Korea.
Jihyoung RohDepartment of Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation (DGMIF), Daegu 41061, Korea.ORCID 0000-0001-8956-3974
Jungki JoDepartment of Medical and Digital Engineering, Hanyang University, Seoul 04763, Korea.ORCID 0000-0002-6080-7493
Korea Electronics Technology Institute · KRHanyang University · KRDaegu-Gyeongbuk Medical Innovation Foundation · KR

Funding

the Bio & Medical Technology Development Program of the National Research Foundation (NRF) 2019M3E5D1A01069353
6 · The paper itself

Abstract

Erection measurements are the most important indicator of male urological disease diagnosis, treatment, and results. Rigiscan has been used widely in studies and diagnoses for nocturnal penile tumescence for evaluating erectile dysfunction by measuring the number and timing of erectile dysfunctions during sleep. However, this device has limitations such as the weight and bulk of the device and has been questioned for its role as a standard for ED Erectile Dysfunction (ED) diagnosis. In this study, we propose a real-time wearable monitoring system that can quantitatively measure the length and circumference of the penis using electronic textiles (E-textile) and carbon nanotube (CNT) sensors. The E-textile sensor is used to measure the length, circumference, and gradient with portability, convenience, and comfort. Sensors were created by coating CNTs on latex for flexibility. The CNT-based latex condom-type sensor in our proposed system shows the length, circumference, and curvature measurements with changes in resistance, and the E-textile performance shows a 1.44% error rate and a cavity radius of 110 to 300. The results of this conceptual study are for supplementary sensor development with a combination of new technologies with alternatives or existing methods for measuring erection function.

Indexed as

Erectile DysfunctionNanotubes, CarbonWearable Electronic DevicesHumansMalePenile ErectionTextilesNanotubes, CarbonCNTerectile dysfunctionE-textileNPTwearable device

Identifiers

PMID35009773
PMCPMC8749841
OpenAlexW4200173604

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.