Evidence map›Paper›PMID 35009628›Full record

ArticleSensors (Basel, Switzerland)2021

Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors.

Hongqiang Xu, Malikeh P Ebrahim, Kareeb Hasan, Fatemeh Heydari, Paul Howley, Mehmet Rasit Yuce

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hongqiang XuDepartment of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC 3800, Australia.
Malikeh P EbrahimDepartment of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC 3800, Australia.
Kareeb HasanDepartment of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC 3800, Australia.ORCID 0000-0002-2548-3382
Fatemeh HeydariDepartment of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC 3800, Australia.
Paul HowleyPlanet Innovation, Box Hill, VIC 3128, Australia.
Mehmet Rasit YuceDepartment of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC 3800, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Vital signs such as heart rate and respiration rate are among the most important physiological signals for health monitoring and medical applications. Impulse radio (IR) ultra-wideband (UWB) radar becomes one of the essential sensors in non-contact vital signs detection. The heart pulse wave is easily corrupted by noise and respiration activity since the heartbeat signal has less power compared with the breathing signal and its harmonics. In this paper, a signal processing technique for a UWB radar system was developed to detect the heart rate and respiration rate. There are four main stages of signal processing: (1) clutter removal to reduce the static random noise from the environment; (2) independent component analysis (ICA) to do dimension reduction and remove noise; (3) using low-pass and high-pass filters to eliminate the out of band noise; (4) modified covariance method for spectrum estimation. Furthermore, higher harmonics of heart rate were used to estimate heart rate and minimize respiration interference. The experiments in this article contain different scenarios including bed angle, body position, as well as interference from the visitor near the bed and away from the bed. The results were compared with the ECG sensor and respiration belt. The average mean absolute error (MAE) of heart rate results is 1.32 for the proposed algorithm.

Indexed as

RadarRespiratory RateAlgorithmsHeart RateMonitoring, PhysiologicRespirationSignal Processing, Computer-AssistedVital Signsblind source separation (BBS)heart rate estimationindependent component analysis (ICA)ultra-wideband (UWB) radar

Identifiers

PMID35009628
PMCPMC8747437

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.