Evidence map›Paper›PMID 35009555›Full record

ArticleSensors (Basel, Switzerland)2021

Machine Learning Methods of Regression for Plasmonic Nanoantenna Glucose Sensing.

Emilio Corcione, Diana Pfezer, Mario Hentschel, Harald Giessen, Cristina Tarín

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.0field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Review
  3. AI-Based Metamaterial Design.ACS applied materials & interfaces · 2024
    Review
  4. Article
  5. Review
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Emilio CorcioneResearch Center SCoPE, Institute for System Dynamics, University of Stuttgart, 70563 Stuttgart, Germany.ORCID 0000-0002-1940-2718
Diana PfezerResearch Center SCoPE, 4th Physics Institute, University of Stuttgart, 70569 Stuttgart, Germany.
Mario HentschelResearch Center SCoPE, 4th Physics Institute, University of Stuttgart, 70569 Stuttgart, Germany.
Harald GiessenResearch Center SCoPE, 4th Physics Institute, University of Stuttgart, 70569 Stuttgart, Germany.
Cristina TarínResearch Center SCoPE, Institute for System Dynamics, University of Stuttgart, 70563 Stuttgart, Germany.
University of Stuttgart · DE

Funding

Deutsche Forschungsgemeinschaft 431314977
6 · The paper itself

Abstract

The measurement and quantification of glucose concentrations is a field of major interest, whether motivated by potential clinical applications or as a prime example of biosensing in basic research. In recent years, optical sensing methods have emerged as promising glucose measurement techniques in the literature, with surface-enhanced infrared absorption (SEIRA) spectroscopy combining the sensitivity of plasmonic systems and the specificity of standard infrared spectroscopy. The challenge addressed in this paper is to determine the best method to estimate the glucose concentration in aqueous solutions in the presence of fructose from the measured reflectance spectra. This is referred to as the inverse problem of sensing and usually solved via linear regression. Here, instead, several advanced machine learning regression algorithms are proposed and compared, while the sensor data are subject to a pre-processing routine aiming to isolate key patterns from which to extract the relevant information. The most accurate and reliable predictions were finally made by a Gaussian process regression model which improves by more than 60% on previous approaches. Our findings give insight into the applicability of machine learning methods of regression for sensor calibration and explore the limitations of SEIRA glucose sensing.

Indexed as

GlucoseMachine LearningAlgorithmsFructoseSpectrophotometry, InfraredFructoseGlucoseartificial neural networkGaussian process regressionglucose sensingmachine learningregression analysissensor calibrationsurface-enhanced infrared absorption spectroscopy

Identifiers

PMID35009555
PMCPMC8747440
OpenAlexW4200208506

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.