Evidence map›Paper›PMID 35009549›Full record

ReviewSensors (Basel, Switzerland)2021

Advances in the Determination of Anabolic-Androgenic Steroids: From Standard Practices to Tailor-Designed Multidisciplinary Approaches.

Lukáš Huml, Jan Tauchen, Silvie Rimpelová, Barbora Holubová, Oldřich Lapčík, Michal Jurášek

Open access · goldAbstract readReview
In one paragraph

Review in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Lukáš HumlDepartment of Chemistry of Natural Compounds, Faculty of Food and Biochemical Technology, University of Chemistry and Technology Prague, 16628 Prague, Czech Republic.ORCID 0000-0002-3288-2656
Jan TauchenDepartment of Food Science, Faculty of Agrobiology, Food and Natural Resources, Czech University of Life Sciences Prague, 16500 Prague, Czech Republic.ORCID 0000-0001-8886-7677
Silvie RimpelováDepartment of Biochemistry and Microbiology, Faculty of Food and Biochemical Technology, University of Chemistry and Technology Prague, 16628 Prague, Czech Republic.ORCID 0000-0002-3008-1396
Barbora HolubováDepartment of Biochemistry and Microbiology, Faculty of Food and Biochemical Technology, University of Chemistry and Technology Prague, 16628 Prague, Czech Republic.ORCID 0000-0002-9339-1981
Oldřich LapčíkDepartment of Chemistry of Natural Compounds, Faculty of Food and Biochemical Technology, University of Chemistry and Technology Prague, 16628 Prague, Czech Republic.
Michal JurášekDepartment of Chemistry of Natural Compounds, Faculty of Food and Biochemical Technology, University of Chemistry and Technology Prague, 16628 Prague, Czech Republic.ORCID 0000-0002-5069-9716
University of Chemistry and Technology, Prague · CZCzech University of Life Sciences Prague · CZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Anabolic-androgenic steroids (AASs), a group of compounds frequently misused by athletes and, unfortunately, also by the general population, have lately attracted global attention; thus, significant demands for more precise, facile, and rapid AAS detection have arisen. The standard methods ordinarily used for AAS determination include liquid and gas chromatography coupled with mass spectrometry. However, good knowledge of steroid metabolism, pretreatment of samples (such as derivatization), and well-trained operators of the instruments are required, making this procedure expensive, complicated, and not routinely applicable. In the drive to meet current AAS detection demands, the scientific focus has shifted to developing novel, tailor-made approaches leading to time- and cost-effective, routine, and field-portable methods for AAS determination in various matrices, such as biological fluids, food supplements, meat, water, or other environmental components. Therefore, herein, we present a comprehensive review article covering recent advances in AAS determination, with a strong emphasis on the increasingly important role of chemically designed artificial sensors, biosensors, and antibody- and fluorescence-based methods.

Indexed as

Anabolic AgentsDoping in SportsAndrogensAthletesHumansSteroidsTestosterone CongenersAnabolic AgentsAndrogensSteroidsTestosterone Congenersanabolic-androgenic steroidsantibodiesbiosensorschemically designed sensorschromatographic detectionfluorescent sensorsimmunoassaysimmunosensorsoligonucleotide-based approachspecific detection

Identifiers

PMID35009549
PMCPMC8747103
OpenAlexW4200048112

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.