Evidence map›Paper›PMID 35009273›Full record

ArticleMaterials (Basel, Switzerland)2021

A Tribological and Ion Released Research of Ti-Materials for Medical Devices.

Daniela Silva, Camila Arcos, Cecilia Montero, Carolina Guerra, Carola Martínez, Xuejie Li, Armelle Ringuedé, Michel Cassir, Kevin Ogle, Danny Guzmán and 3 more

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Daniela SilvaDepartamento de Ingeniería Mecánica y Metalúrgica, Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago 7820436, Chile.
Camila ArcosDepartamento de Ingeniería Mecánica y Metalúrgica, Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago 7820436, Chile.ORCID 0000-0001-6285-1319
Cecilia MonteroDepartamento de Ingeniería Metalúrgica, Facultad de Ingeniería, Universidad de Santiago, Santiago 9170022, Chile.ORCID 0000-0002-9089-8373
Carolina GuerraDepartamento de Ingeniería Mecánica y Metalúrgica, Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago 7820436, Chile.
Carola MartínezDepartamento de Ingeniería de Obras Civiles, Universidad de La Frontera, Temuco 4780000, Chile.ORCID 0000-0001-5247-6703
Xuejie LiCNRS, Institut de Recherche de Chimie de Paris, Chimie ParisTech, PSL University, 75005 Paris, France.
Armelle RinguedéCNRS, Institut de Recherche de Chimie de Paris, Chimie ParisTech, PSL University, 75005 Paris, France.
Michel CassirCNRS, Institut de Recherche de Chimie de Paris, Chimie ParisTech, PSL University, 75005 Paris, France.
Kevin OgleCNRS, Institut de Recherche de Chimie de Paris, Chimie ParisTech, PSL University, 75005 Paris, France.
Danny GuzmánDepartamento de Ingeniería en Metalurgia, Universidad de Atacama, Copiapó 1530000, Chile.ORCID 0000-0002-8020-9247
Claudio AguilarDepartamento de Ingeniería Metalúrgica y de Materiales, Universidad Técnica Federico Santa María, Valparaíso 2390123, Chile.ORCID 0000-0002-9013-5835
Maritza PáezDepartamento de Química de los Materiales, Facultad de Química y Biología, Universidad de Santiago de Chile, Santiago 9170022, Chile.ORCID 0000-0001-5881-884X
Mamié SancyEscuela de Construcción Civil, Pontificia Universidad Católica de Chile, Santiago 7820436, Chile.

Funding

Comisión Nacional de Investigación Científica y Tecnológica 116060415Comisión Nacional de Investigación Científica y Tecnológica 1180843Comisión Nacional de Investigación Científica y Tecnológica 170033Comisión Nacional de Investigación Científica y Tecnológica 170087Universidad técnica Federico Santa María Programa de Incentivo a la Iniciación Científica
6 · The paper itself

Abstract

The increase in longevity worldwide has intensified the use of different types of prostheses for the human body, such as those used in dental work as well as in hip and knee replacements. Currently, Ti-6Al-4V is widely used as a joint implant due to its good mechanical properties and durability. However, studies have revealed that this alloy can release metal ions or particles harmful to human health. The mechanisms are not well understood yet and may involve wear and/or corrosion. Therefore, in this work, commercial pure titanium and a Ti-6Al-4V alloy were investigated before and after being exposed to a simulated biological fluid through tribological tests, surface analysis, and ionic dissolution characterization by ICP-AES. Before exposure, X-ray diffraction and optical microscopy revealed equiaxed α-Ti in both materials and β-Ti in Ti-6Al-4V. Scratch tests exhibited a lower coefficient of friction for Ti-6Al-4V alloy than commercially pure titanium. After exposure, X-ray photoelectron spectroscopy and surface-enhanced Raman spectroscopy results showed an oxide film formed by TiO

Indexed as

ion releasescratch testsurface characterizationTi-6Al-4V

Identifiers

PMID35009273
PMCPMC8746336

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.