Evidence map›Paper›PMID 35005014›Full record

ArticleBioMed research international2021

Development and Validation of a Mixed Reality Configuration of a Simulator for a Minimally Invasive Spine Surgery Using the Workspace of a Haptic Device and Simulator Users.

Sneha Patel, Sami Alkadri, Mark Driscoll

Open access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.8field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Virtual reality for surgical training in balloon kyphoplasty procedure.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024
    Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Sneha PatelDepartment of Mechanical Engineering, McGill University, MacDonald Engineering Building, 817 Rue Sherbrooke Ouest #270, Montréal, Québec, Canada H3A 0C3.ORCID https://orcid.org/0000-0001-9511-9263
Sami AlkadriDepartment of Mechanical Engineering, McGill University, MacDonald Engineering Building, 817 Rue Sherbrooke Ouest #270, Montréal, Québec, Canada H3A 0C3.
Mark DriscollDepartment of Mechanical Engineering, McGill University, MacDonald Engineering Building, 817 Rue Sherbrooke Ouest #270, Montréal, Québec, Canada H3A 0C3.ORCID https://orcid.org/0000-0002-5348-6054
McGill University · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Most surgical simulators leverage virtual or bench models to simulate reality. This study proposes and validates a method for workspace configuration of a surgical simulator which utilizes a haptic device for interaction with a virtual model and a bench model to provide additional tactile feedback based on planned surgical manoeuvers. Numerical analyses were completed to determine the workspace and position of a haptic device, relative to the bench model, used in the surgical simulator, and the determined configuration was validated using device limitations and user data from surgical and nonsurgical users. For the validation, surgeons performed an identical surgery on a cadaver prior to using the simulator, and their trajectories were then compared to the determined workspace for the haptic device. The configuration of the simulator was determined appropriate through workspace analysis and the collected user trajectories. Statistical analyses suggest differences in trajectories between the participating surgeons which were not affected by the imposed haptic workspace. This study, therefore, demonstrates a method to optimally position a haptic device with respect to a bench model while meeting the manoeuverability needs of a surgical procedure. The validation method identified workspace position and user trajectory towards ideal configuration of a mixed reality simulator.

Indexed as

Augmented RealityComputer SimulationFeedbackHaptic InterfacesHumansMinimally Invasive Surgical ProceduresSpineUser-Computer Interface

Identifiers

PMID35005014
PMCPMC8741356
OpenAlexW4206298414

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked