Evidence map›Paper›PMID 35003551›Full record

ArticleThe journal of advanced prosthodontics2021

Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based.

Tobias Graf, Jan-Frederik Güth, Christian Diegritz, Anja Liebermann, Josef Schweiger, Oliver Schubert

Abstract read
In one paragraph

Article in The journal of advanced prosthodontics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tobias GrafDepartment of Prosthodontics, Center for Dentistry and Oral Medicine, Johann Wolfgang Goethe University, Frankfurt am Main, Germany.ORCID https://orcid.org/0000-0002-2391-5399
Jan-Frederik GüthDepartment of Prosthodontics, Center for Dentistry and Oral Medicine, Johann Wolfgang Goethe University, Frankfurt am Main, Germany.ORCID https://orcid.org/0000-0002-0693-0810
Christian DiegritzDepartment of Conservative Dentistry and Periodontics, University Hospital, LMU Munich, Munich, Germany.ORCID https://orcid.org/0000-0002-1034-6844
Anja LiebermannDepartment of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany.ORCID https://orcid.org/0000-0002-1385-2195
Josef SchweigerDepartment of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany.ORCID https://orcid.org/0000-0002-7813-4047
Oliver SchubertDepartment of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany.ORCID https://orcid.org/0000-0002-2630-2635

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND

methodsA titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (

resultsMedian and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (±SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 ± 7 µm in group CF and 34 ± 6 µm in group PC. RMSE of total adjustments was 61 ± 11 µm in group PC. Quality of occlusal contacts was better in group CF.

conclusionTime effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable.

Indexed as

3D printingCAD-CAMCast-freeDigital workflowSingle implant crownTime-efficiency

Identifiers

PMID35003551
PMCPMC8712114

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.