Evidence map›Paper›PMID 35002654›Full record

ArticleFrontiers in human neuroscience2021

Relationships Between Cardiovascular Autonomic Profile and Work Ability in Patients With Pure Autonomic Failure.

Antonio R Zamunér, Maura Minonzio, Dana Shiffer, Roberto Fornerone, Beatrice Cairo, Alberto Porta, Stefano Rigo, Raffaello Furlan, Franca Barbic

Open access · goldAbstract read
In one paragraph

Article in Frontiers in human neuroscience, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Observational
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Antonio R ZamunérLaboratory of Clinical Research in Kinesiology, Department of Kinesiology, Universidad Católica del Maule, Talca, Chile.
Maura MinonzioInternal Medicine, IRCCS Humanitas Research Hospital, Milan, Italy.
Dana ShifferInternal Medicine, IRCCS Humanitas Research Hospital, Milan, Italy.
Roberto ForneroneInternal Medicine, IRCCS Humanitas Research Hospital, Milan, Italy.
Beatrice CairoDepartment of Biomedical Sciences for Health, University of Milan, Milan, Italy.
Alberto PortaDepartment of Biomedical Sciences for Health, University of Milan, Milan, Italy.
Stefano RigoInternal Medicine, IRCCS Humanitas Research Hospital, Milan, Italy.
Raffaello FurlanInternal Medicine, IRCCS Humanitas Research Hospital, Milan, Italy.
Franca BarbicInternal Medicine, IRCCS Humanitas Research Hospital, Milan, Italy.
IRCCS Humanitas Research Hospital · ITHumanitas University · ITCatholic University of the Maule · CLIRCCS Policlinico San Donato · ITUniversity of Milan · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pure autonomic failure (PAF) is a rare disorder belonging to the group of synucleinopathies, characterized by autonomic nervous system degeneration. Severe orthostatic intolerance with recurrent syncope while standing are the two most disabling manifestations. Symptoms may start at middle age, thus affecting people at their working age. The aims of this study were to evaluate the autonomic and work ability impairment of a group of PAF patients and assess the relationships between cardiovascular autonomic control and work ability in these patients. Eleven PAF patients (age 57.3 ± 6.7 years), engaged in work activity, participated in the study. They completed the Composite Autonomic Symptom Score (COMPASS-31, range 0 no symptom-100 maximum symptom intensity) and Work Ability questionnaires (Work Ability Index, WAI, range 7-49; higher values indicate better work ability and lower values indicating unsatisfactory or jeopardized work ability). Electrocardiogram, blood pressure and respiratory activity were continuously recorded for 10 min while supine and during 75° head-up tilt (HUT). Autoregressive spectral analysis of cardiac cycle length approximated as the time distance between two consecutive R-wave peaks (RR) and systolic arterial pressure (SAP) variabilities provided the power in the high frequency (HF, 0.15-0.40 Hz) and low frequency (LF, 0.04-0.15 Hz) bands of RR and SAP variabilities. Cardiac sympatho-vagal interaction was assessed by LF to HF ratio (LF/HF), while the LF power of SAP (LF

Indexed as

autonomic nervous systemblood pressureheart rate variabilityorthostatic hypotensionpower spectrum analysispure autonomic failure (PAF)work ability

Identifiers

PMID35002654
PMCPMC8733607
OpenAlexW4200109096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.