Evidence map›Paper›PMID 35001500›Full record

ReviewHemodialysis international. International Symposium on Home Hemodialysis2022

Cost of the quanta SC+ hemodialysis system for self-care in the United Kingdom.

Thomas W Ferguson, Gerard D Harper, John E Milad, Paul V J Komenda

Open access · hybridAbstract readReview
In one paragraph

Review in Hemodialysis international. International Symposium on Home Hemodialysis, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Cost of the quanta SC+ hemodialysis system for self-care in the United Kingdom.Hemodialysis international. International Symposium on Home Hemodialysis · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Thomas W FergusonDepartment of Nephrology, Seven Oaks Hospital Chronic Disease Innovation Centre, Winnipeg, Manitoba, Canada.
Gerard D HarperQuanta Dialysis Technologies Limited, Alcester, UK.
John E MiladQuanta Dialysis Technologies Limited, Alcester, UK.
Paul V J KomendaDepartment of Nephrology, Seven Oaks Hospital Chronic Disease Innovation Centre, Winnipeg, Manitoba, Canada.
Seven Oaks General Hospital · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionNew personal hemodialysis systems, such as the quanta SC+, are being developed; these systems are smaller and simpler to use while providing the clearances of conventional systems. Increasing the uptake of lower-intensity assistance and full self-care dialysis may provide economic benefits to the public health payer. In the United Kingdom, most hemodialysis patients currently receive facility-based dialysis costing more than £36,350 per year including patient transport. As such, we aimed to describe the annual costs of using the SC+ hemodialysis system in the United Kingdom for 3×-weekly and 3.5×-weekly dialysis regimens, for self-care hemodialysis provided both in-center and at home.

methodsWe applied a cost minimization approach. Costs for human resources, equipment, and consumables were sourced from the dialysis machine developer (Quanta Dialysis Technologies) based upon discussions with dialysis providers. Facility overhead expenses and transport costs were taken from a review of the literature.

findingsAnnual costs associated with the use of the SC+ hemodialysis system were estimated to be £26,642 for hemodialysis provided 3× weekly as home self-care; £30,235 for hemodialysis provided 3× weekly as self-care in-center; £29,866 for hemodialysis provided 3.5× weekly as home self-care; and £36,185 for hemodialysis provided 3.5× weekly as self-care in-center. DISCUSSION: We found that the SC+ hemodialysis system offers improved cost-effectiveness for both 3×-weekly and 3.5×-weekly self-care dialysis performed at home or as self-care in-center versus fully assisted dialysis provided 3× weekly with conventional machines in facilities.

Indexed as

Kidney Failure, ChronicPeritoneal DialysisCost-Benefit AnalysisHemodialysis, HomeHumansRenal DialysisSelf Carecost effectivenessdialysiseconomic analysishemodialysis

Identifiers

PMID35001500
PMCPMC9544577
OpenAlexW4206405320

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.