Evidence map›Paper›PMID 35000609›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2022

Efficient non-contrast enhanced 3D Cartesian cardiovascular magnetic resonance angiography of the thoracic aorta in 3 min.

Anastasia Fotaki, Camila Munoz, Yaso Emanuel, Alina Hua, Filippo Bosio, Karl P Kunze, Radhouene Neji, Pier Giorgio Masci, René M Botnar, Claudia Prieto

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.1field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Highly efficient free-breathing 3D whole-heart imaging in 3-min: single center study in adults with congenital heart disease.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Article
  6. Article
  7. Article
  8. Highly efficient, free-breathing whole-chest equilibrium phase bT1RESS MR angiography: Initial clinical experience.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
    Article
  9. Feasibility and reproducibility of semi-automated magnetic resonance angiography measurements of the thoracic aorta using commercial software.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Anastasia FotakiDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor-Lambeth Wing, Westminster Bridge Road, London, SE1 7EH, UK. Anastasia.fotaki@kcl.ac.uk.ORCID 0000-0002-0353-5778
Camila MunozDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor-Lambeth Wing, Westminster Bridge Road, London, SE1 7EH, UK.
Yaso EmanuelDepartment of Cardiology, NHS Foundation Trust, Guy's and St Thomas, London, UK.
Alina HuaDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor-Lambeth Wing, Westminster Bridge Road, London, SE1 7EH, UK.
Filippo BosioDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor-Lambeth Wing, Westminster Bridge Road, London, SE1 7EH, UK.
Karl P KunzeDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor-Lambeth Wing, Westminster Bridge Road, London, SE1 7EH, UK.
Radhouene NejiDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor-Lambeth Wing, Westminster Bridge Road, London, SE1 7EH, UK.
Pier Giorgio MasciDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor-Lambeth Wing, Westminster Bridge Road, London, SE1 7EH, UK.
René M BotnarDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor-Lambeth Wing, Westminster Bridge Road, London, SE1 7EH, UK.
Claudia PrietoDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor-Lambeth Wing, Westminster Bridge Road, London, SE1 7EH, UK.
St Thomas' Hospital · GBGuy's and St Thomas' NHS Foundation Trust · GB

Funding

British Heart Foundation FS/20/13/34857British Heart Foundation FS/CRTF/20/24011British Heart Foundation PG/18/59/33955Department of HealthMedical Research Council MR/L009676/1Wellcome Trust NS/A000049/1
6 · The paper itself

Abstract

backgroundThe application of cardiovascular magnetic resonance angiography (CMRA) for the assessment of thoracic aortic disease is often associated with prolonged and unpredictable acquisition times and residual motion artefacts. To overcome these limitations, we have integrated undersampled acquisition with image-based navigators and inline non-rigid motion correction to enable a free-breathing, contrast-free Cartesian CMRA framework for the visualization of the thoracic aorta in a short and predictable scan of 3 min.

methods35 patients with thoracic aortic disease (36 ± 13y, 14 female) were prospectively enrolled in this single-center study. The proposed 3D T2-prepared balanced steady state free precession (bSSFP) sequence with image-based navigator (iNAV) was compared to the clinical 3D T2-prepared bSSFP with diaphragmatic-navigator gating (dNAV), in terms of image acquisition time. Three cardiologists blinded to iNAV vs. dNAV acquisition, recorded image quality scores across four aortic segments and their overall diagnostic confidence. Contrast ratio (CR) and relative standard deviation (RSD) of signal intensity (SI) in the corresponding segments were estimated. Co-axial aortic dimensions in six landmarks were measured by two readers to evaluate the agreement between the two methods, along with inter-observer and intra-observer agreement. Kolmogorov-Smirnov test, Mann-Whitney U (MWU), Bland-Altman analysis (BAA), intraclass correlation coefficient (ICC) were used for statistical analysis.

resultsThe scan time for the iNAV-based approach was significantly shorter (3.1 ± 0.5 min vs. 12.0 ± 3.0 min for dNAV, P = 0.005). Reconstruction was performed inline in 3.0 ± 0.3 min. Diagnostic confidence was similar for the proposed iNAV versus dNAV for all three reviewers (Reviewer 1: 3.9 ± 0.3 vs. 3.8 ± 0.4, P = 0.7; Reviewer 2: 4.0 ± 0.2 vs. 3.9 ± 0.3, P = 0.4; Reviewer 3: 3.8 ± 0.4 vs. 3.7 ± 0.6, P = 0.3). The proposed method yielded higher image quality scores in terms of artefacts from respiratory motion, and non-diagnostic images due to signal inhomogeneity were observed less frequently. While the dNAV approach outperformed the iNAV method in the CR assessment, the iNAV sequence showed improved signal homogeneity along the entire thoracic aorta [RSD SI 5.1 (4.4, 6.5) vs. 6.5 (4.6, 8.6), P = 0.002]. BAA showed a mean difference of < 0.05 cm across the 6 landmarks between the two datasets. ICC showed excellent inter- and intra-observer reproducibility.

conclusionsThoracic aortic iNAV-based CMRA with fast acquisition (~ 3 min) and inline reconstruction (3 min) is proposed, resulting in high diagnostic confidence and reproducible aortic measurements.

Indexed as

Aorta, ThoracicMagnetic Resonance AngiographyFemaleHeartHumansImaging, Three-DimensionalPredictive Value of TestsReproducibility of ResultsiNAVNon-rigid motion correctionThoracic aortic diseaseUndersampled Cartesian MRA

Identifiers

PMID35000609
PMCPMC8744314
OpenAlexW4206483815

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.