Evidence map›Paper›PMID 34997396›Full record

ArticleMagma (New York, N.Y.)2022

Towards an integrated neonatal brain and cardiac examination capability at 7 T: electromagnetic field simulations and early phantom experiments using an 8-channel dipole array.

Jérémie Clément, Raphaël Tomi-Tricot, Shaihan J Malik, Andrew Webb, Joseph V Hajnal, Özlem Ipek

Abstract read
In one paragraph

Article in Magma (New York, N.Y.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jérémie ClémentDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
Raphaël Tomi-TricotMR Research Collaborations, Siemens Healthcare Limited, Frimley, UK.
Shaihan J MalikDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
Andrew WebbDepartment of Radiology, C. J Gorter Center for High Field MRI, Leiden University Medical Center, Leiden, The Netherlands.
Joseph V HajnalDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
Özlem IpekDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. ozlem.ipek@kcl.ac.uk.ORCID http://orcid.org/0000-0001-5233-1600

Funding

Wellcome Trust 201526/Z/16/Z
6 · The paper itself

Abstract

objectiveNeonatal brain and cardiac imaging would benefit from the increased signal-to-noise ratio levels at 7 T compared to lower field. Optimal performance might be achieved using purpose designed RF coil arrays. In this study, we introduce an 8-channel dipole array and investigate, using simulations, its RF performances for neonatal applications at 7 T.

methodsThe 8-channel dipole array was designed and evaluated for neonatal brain/cardiac configurations in terms of SAR efficiency (ratio between transmit-field and maximum specific-absorption-rate level) using adjusted dielectric properties for neonate. A birdcage coil operating in circularly polarized mode was simulated for comparison. Validation of the simulation model was performed on phantom for the coil array.

resultsThe 8-channel dipole array demonstrated up to 46% higher SAR efficiency levels compared to the birdcage coil in neonatal configurations, as the specific-absorption-rate levels were alleviated. An averaged normalized root-mean-square-error of 6.7% was found between measured and simulated transmit field maps on phantom.

conclusionThe 8-channel dipole array design integrated for neonatal brain and cardiac MR was successfully demonstrated, in simulation with coverage of the baby and increased SAR efficiency levels compared to the birdcage. We conclude that the 8Tx-dipole array promises safe operating procedures for MR imaging of neonatal brain and heart at 7 T.

Indexed as

Electromagnetic FieldsMagnetic Resonance ImagingBrainEquipment DesignHumansInfant, NewbornPhantoms, ImagingSignal-To-Noise Ratio7 TNeonatal brain and heartNeonate dipole coil arrayParallel-transmitSAR reductionUltra-high field

Identifiers

PMID34997396
PMCPMC9463228

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.