Evidence map›Paper›PMID 34997283›Full record

ArticleNeuroradiology2022

Quantitative assessment of microstructural evolution of intracranial aneurysm wall by vessel wall imaging.

Hidenori Endo, Naoko Mori, Shunji Mugikura, Kuniyasu Niizuma, Shunsuke Omodaka, Kei Takase, Teiji Tominaga

Abstract read
PubMed Publisher
In one paragraph

Article in Neuroradiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Need for Contrast-enhanced MR Imaging Protocols and Quantitative Assessment of Wall Enhancement for Vessel Wall Imaging in Various Intracranial Arterial Diseases.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hidenori EndoDepartment of Neurosurgery, Tohoku University Graduate School of Medicine, Sendai, Japan.ORCID http://orcid.org/0000-0003-1472-6032
Naoko MoriDepartment of Diagnostic Radiology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, Japan. naokomori7127@gmail.com.ORCID http://orcid.org/0000-0002-8700-9731
Shunji MugikuraDepartment of Diagnostic Radiology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, Japan.ORCID http://orcid.org/0000-0002-9138-610X
Kuniyasu NiizumaDepartment of Neurosurgical Engineering and Translational Neuroscience, Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan.ORCID http://orcid.org/0000-0001-9282-6499
Shunsuke OmodakaDepartment of Neurosurgery, Tohoku University Graduate School of Medicine, Sendai, Japan.ORCID http://orcid.org/0000-0001-9660-7795
Kei TakaseDepartment of Diagnostic Radiology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, Japan.ORCID http://orcid.org/0000-0003-0931-9942
Teiji TominagaDepartment of Neurosurgery, Tohoku University Graduate School of Medicine, Sendai, Japan.ORCID http://orcid.org/0000-0003-3411-2900

Funding

Japan Society for the Promotion of Science London 18K07742
6 · The paper itself

Abstract

purposeThis study aimed to evaluate new quantitative parameters of aneurysm wall enhancement (AWE) on magnetic resonance vessel wall imaging (VWI) in differentiating between the stable and evolving unruptured intracranial aneurysms (UIAs).

methodsThirty-eight consecutive patients with UIAs (27 stable and 11 evolving) underwent VWI with contrast-enhanced 3D T1 volume isotropic turbo spin echo acquisition. The voxel-based enhancement maps were created using pre- and post-contrast images. The aneurysmal lumen with signal suppression by black-blood method was segmented. Then, one voxel outer and inner layers of the lumen contour were automatically segmented. The shape features of the aneurysms and AWE of the two layers were compared between stable and evolving groups.

resultsThe shape features, including aneurysm volume, surface, and compacity were significantly different between the stable and evolving groups (P = 0.024, 0.028, and 0.033, respectively). Stable and evolving groups also differed significantly in the AWE at the union of outer and inner layers of the aneurysm wall (P = 0.0082) but not in that of the outer or inner layer alone. Multivariate logistic regression analysis revealed significant differences in aneurysm volume, surface, and AWE at the union of outer and inner layers between the two groups (P = 0.0029, 0.0092, and 0.0033, respectively). Receiver operating characteristics curve analysis revealed that the area under the curve of the logistic regression model was 0.89.

conclusionQuantitative combined analysis of aneurysm shape features and AWE of the union of outer and inner layers were effective for differentiating between stable and evolving UIAs.

Indexed as

Intracranial AneurysmCerebral AngiographyHumansMagnetic Resonance ImagingAneurysm wall enhancementEvolvingIntracranial aneurysmMagnetic resonance imagingVessel wall imaging

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.