Evidence map›Paper›PMID 34996409›Full record

Trial reportBMC musculoskeletal disorders2022

Fixation of intraoperative proximal femoral fractures during THA using two versus three cerclage wires - a biomechanical study.

Toni Wendler, Melanie Edel, Robert Möbius, Johannes Fakler, Georg Osterhoff, Dirk Zajonz

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Toni Wendler *ZESBO - Center for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany. toni.wendler@medizin.uni-leipzig.de.ORCID http://orcid.org/0000-0001-7890-178X
Melanie Edel *ZESBO - Center for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany.
Robert MöbiusDepartment of Neurosurgery, Leipzig University, Leipzig, Germany.
Johannes FaklerDepartment of Orthopaedic, Trauma and Plastic Surgery, Leipzig University, Leipzig, Germany.
Georg OsterhoffDepartment of Orthopaedic, Trauma and Plastic Surgery, Leipzig University, Leipzig, Germany.
Dirk ZajonzZESBO - Center for Research on Musculoskeletal Systems, Leipzig University, Semmelweisstraße 14, 04103, Leipzig, Germany.

Funding

Deutsche Arthrose-Hilfe e.V. P400-A687-Josten-EP6-zajo2-hüfte-op-l-10k-2017-18
6 · The paper itself

Abstract

backgroundIntraoperative proximal femoral fractures (IPFF) are relevant complications during total hip arthroplasty. Fixation using cerclage wires (CW) represents a minimally-invasive technique to address these fractures through the same surgical approach. The goal of treatment is to mobilise the patient as early as possible, which requires high primary stability. This study aimed to compare different cerclage wire configurations fixing IPFF with regard to biomechanical primary stability.

methodsStandardised IPFF (type II, Modified Mallory Classification) were created in human fresh frozen femora and were fixed either by two or three CW (1.6 mm, stainless steel). All cadaveric specimens (n = 42) were randomised to different groups (quasi-static, dynamic) or subgroups (2 CW, 3 CW) stratified by bone mineral density determined by Dual Energy X-ray Absorptiometry. Using a biomechanical testing setup, quasi-static and dynamic cyclic failure tests were carried out. Cyclic loading started from 200 N to 500 N at 1 Hz with increasing peak load by 250 N every 100 cycles until failure occurred or maximum load (5250 N) reached. The change of fracture gap size was optically captured.

resultsNo significant differences in failure load after quasi-static (p = 0.701) or dynamic cyclic loading (p = 0.132) were found between the experimental groups. In the quasi-static load testing, all constructs resisted 250% of the body weight (BW) of their corresponding body donor. In the dynamic cyclic load testing, all but one construct (treated by 3 CW) resisted 250% BW.

conclusionsBased on this in vitro data, both two and three CW provided sufficient primary stability according to the predefined minimum failure load (250% BW) to resist. The authors recommend the treatment using two CW because it reduces the risk of vascular injury and shortens procedure time.

Indexed as

Arthroplasty, Replacement, HipFemoral FracturesBiomechanical PhenomenaBone WiresFracture Fixation, InternalHumansBiomechanical studyCementless stemCerclage wiringIntraoperative fractureProximal femoral fractureTotal hip arthroplasty

Identifiers

PMID34996409
PMCPMC8742345

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.